2012
DOI: 10.1107/s0021889812021152
|View full text |Cite
|
Sign up to set email alerts
|

DAJUST: a suite of computer programs for pattern matching, space-group determination and intensity extraction from powder diffraction data

Abstract: DAJUSTis the generic name of a software package for powder diffraction formed by the core programsAJUSTandSGAID(both written in Fortran) controlled by an easy-to-use Java user interface (DAJUST_UI). WhileAJUSTperforms whole-pattern matching (cell-parameter refinement, profile fitting and intensity extraction),SGAIDprovides a list of the most probable space groups. For the extraction of the integrated intensities,AJUSTuses the Le Bail procedure but with a different formula for refining the integrated intensitie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
38
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 41 publications
(39 citation statements)
references
References 16 publications
1
38
0
Order By: Relevance
“…44) and the intensities extracted with DAjust soware 45 were introduced in the direct-space solution program TALP 46 to solve the crystal structure. Data of Edimim [FeCl 4 ] at 100 K were collected at the MSPD beamline (BL04) of ALBA Synchrotron using the microstrip MYTHEN-II detector (six modules, 1280 channels per module, 50 mm per channel, sample-to-detector distance 550 mm) with an energy of 20 keV (rened wavelength of 0.6193Å).…”
Section: Structural Characterizationmentioning
confidence: 99%
“…44) and the intensities extracted with DAjust soware 45 were introduced in the direct-space solution program TALP 46 to solve the crystal structure. Data of Edimim [FeCl 4 ] at 100 K were collected at the MSPD beamline (BL04) of ALBA Synchrotron using the microstrip MYTHEN-II detector (six modules, 1280 channels per module, 50 mm per channel, sample-to-detector distance 550 mm) with an energy of 20 keV (rened wavelength of 0.6193Å).…”
Section: Structural Characterizationmentioning
confidence: 99%
“…The crystal structure of 1 and 2 was successfully solved following an ab initio methodology. The integrated intensities were extracted using the program DAJUST [35], and the crystal structure were solved by direct methods using the program XLENS [36]. For Compound 1, a starting structural model containing a total of 31 atoms in the asymmetric part of the unit cell was obtained.…”
Section: Structural Characterizationmentioning
confidence: 99%
“…41 Indexing was carried out using TREOR90. 42 The model-free profile refinement was made using Dajust, 43 using Mythen-II data. The crystal structure was solved in � by applying cluster-based Patterson-function direct methods (Xlens_PD6).…”
Section: Synthesismentioning
confidence: 99%