1992
DOI: 10.1111/j.1365-2621.1992.tb05429.x
|View full text |Cite
|
Sign up to set email alerts
|

Hypoxanthine Ratio Determination in Fish Extract Using Capillary Electrophoresis and Immobilized Enzymes

Abstract: Fish freshness was assessed using capillary electrophoresis and an immobilized enzyme procedure to monitor degradation of inosine-Smonophosphate (IMP), inosine (HxR) and hypoxanthine (I-Ix). The enzymatic method used an amperometric probe at + 0.7 V (platinum vs silver/silver chloride) with immobilized xanthine oxidase, catalase, nucleoside phosphorylase, and nucleotidase for converting I-Ix, HxR or IMP to uric acid. Capillary electrophoresis resolved IMP, inosine and Hx by migration rates resulting from an ap… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
50
1

Year Published

1998
1998
2014
2014

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 91 publications
(56 citation statements)
references
References 15 publications
(13 reference statements)
1
50
1
Order By: Relevance
“…Luong et al (1992) highlight that, for some species, K and Ki values do not adequately reflect the alterations that occur, because they rapidly increase and then, they remain more or less constant. This is caused by a rapid accumulation of HxR and Hx.…”
Section: Journal Of Food Studiesmentioning
confidence: 99%
See 1 more Smart Citation
“…Luong et al (1992) highlight that, for some species, K and Ki values do not adequately reflect the alterations that occur, because they rapidly increase and then, they remain more or less constant. This is caused by a rapid accumulation of HxR and Hx.…”
Section: Journal Of Food Studiesmentioning
confidence: 99%
“…Many methods have been reported for the analysis of ATP and its degradation products, such as the use of cationic-ionic exchange columns (Saito et al 1959), enzyme sensor system (Karube et al 1984), capillary electrophoresis (Luong et al, 1992) and high performance liquid chromatography (HPLC), the latter as the most frequently described in several studies (Burns et al, 1985;Lakshmanan et al, 1996;Vázquez-Ortiz et al, 1996;Özogul et al, 2000;Huidobro et al, 2001;Özogul et al, 2008;Siripatrawan et al, 2009;Uriarte-Montoya et al, 2010;Özogul et al, 2011). Perchloric acid is the reagent more frequently used in the extraction stage.…”
Section: Journal Of Food Studiesmentioning
confidence: 99%
“…Hypoxanthine, xanthine, and uric acid are metabolites of purine bases in nucleic acids through a series of biochemical pathways [2]. In addition, hypoxanthine and xanthine have been linked to off-flavors in food and are important markers of fish freshness [3,4]. The concentration of uric acid is an important diagnostic parameter in the evaluation of renal diseases [2].…”
Section: Introductionmentioning
confidence: 99%
“…Since adenosine nucleotides disappear very quickly, Karube et al (1984) proposed the Ki value, which excludes ATP, ADP and AMP, as an index of freshness quality. H values have been described by Luong et al (1992) as an index of freshness quality. Additionally, the G and P values are reported to be most useful with lean fish.…”
Section: Introductionmentioning
confidence: 99%