2017
DOI: 10.1016/j.elecom.2017.05.007
|View full text |Cite
|
Sign up to set email alerts
|

Hydrogen mapping in an aluminum alloy using an alternating current scanning electrochemical microscope (AC-SECM)

Abstract: OATAO is an open access repository that collects the work of Toulouse researchers and makes it freely available over the web where possible. A B S T R A C TMeasurements using an alternating current scanning electrochemical microscope (AC-SECM) were performed on a 2024 aluminum alloy pre-charged with hydrogen. A gradient in AC current magnitude was observed over several hundreds of microns on the side perpendicular to the charging side. After heat treatment at 130°C for 2 h, the current gradient disappeared. C… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 18 publications
2
12
0
Order By: Relevance
“…The H enrichment of those interfaces enhances their electrochemical reactivity (Fig. 6d), promoting their dissolution, as shown by AC-SECM measurements [28] so that IGC defects can progress laterally and become more and more branched when the duration of exposure to the chloride solution increased (insert in Fig. 2a).…”
Section: New Insight Into the Igc Mechanism For Aa 2024mentioning
confidence: 93%
See 3 more Smart Citations
“…The H enrichment of those interfaces enhances their electrochemical reactivity (Fig. 6d), promoting their dissolution, as shown by AC-SECM measurements [28] so that IGC defects can progress laterally and become more and more branched when the duration of exposure to the chloride solution increased (insert in Fig. 2a).…”
Section: New Insight Into the Igc Mechanism For Aa 2024mentioning
confidence: 93%
“…The samples were 1 cm 3 cubes, the precharging duration was 40 h and the precharging potential was -0.8 V vs SCE; these parameters allowed a sufficient amount of H to be introduced inside the sample in a reasonable amount of time. The precharging side was polished with diamond paste down to 3 μm with distilled water as a lubricant before precharging; it was chosen to be perpendicular to the elongated grain direction (L) [27,28]. Therefore, one of the long transverse (LT) -short transverse (ST) sides of the samples was exposed to the electrolyte; all the other sides were protected by a varnish.…”
Section: H Prechargingmentioning
confidence: 99%
See 2 more Smart Citations
“…SECM is a well‐established scanning technique, with high resolution to monitor corrosion processes, where a microelectrode is positioned close to a surface for localized detection of electrochemically active species . SECM and SECM integrated with electrochemical atomic force microscopy (SECM/AFM) have been applied to study the local corrosion of aluminum alloys in different situations. However, the use of SECM to investigate the local corrosion processes and the influence of the near surface deformed layer (NSDL) and its removal by polishing on the local electrochemical activities of the on new generation Al‐Li alloys, such as the AA2098, is rare in the literature.…”
Section: Introductionmentioning
confidence: 99%