2004
DOI: 10.4314/gjgs.v2i1.18686
|View full text |Cite
|
Sign up to set email alerts
|

Hydro-Geoelctrical Study in Jalingo Metropolis and Environs of Taraba Staste, Ne Nigeria

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Also mica, clay, feldspar have low resistivity because of their permeabilties.The Vertical Electrical Sounding (VES) has proved very popular with Ground water prospecting and engineering investigation due to simplicity of the techniques.The electrical geophysical survey method is the detection of the surface effect produced by the flow of electric current inside the earth.According to Nur et al (2001), nineteen Schlumberger vertical electrical soundings (VES) were carried out during a field survey in the northeast, part of Michika. The results obtained are Details of the model parameters and the mathematical formulae used for this study can be found in Mbonu et al (1991), and Nur and Ayuni (2004). According to (nur et al 2006), the qualitative and quantitative interpretation of the nineteen vertical electrical sounding (VES) has helped in the determination of the depth of the basement in the study area.…”
Section: IIImentioning
confidence: 99%
“…Also mica, clay, feldspar have low resistivity because of their permeabilties.The Vertical Electrical Sounding (VES) has proved very popular with Ground water prospecting and engineering investigation due to simplicity of the techniques.The electrical geophysical survey method is the detection of the surface effect produced by the flow of electric current inside the earth.According to Nur et al (2001), nineteen Schlumberger vertical electrical soundings (VES) were carried out during a field survey in the northeast, part of Michika. The results obtained are Details of the model parameters and the mathematical formulae used for this study can be found in Mbonu et al (1991), and Nur and Ayuni (2004). According to (nur et al 2006), the qualitative and quantitative interpretation of the nineteen vertical electrical sounding (VES) has helped in the determination of the depth of the basement in the study area.…”
Section: IIImentioning
confidence: 99%
“…The area lies within latitudes 10°32'N to 10°41'N and longitudes 13°19'E to 13°25'E, and it is bounded to the West by Borno State, to the East by Republic of Cameroon, to the North by Madagali Local Government Area and to the South by Mubi Local Government Area respectively. The area is relatively flat in the west and hilly in the eastern part, and despite the hilly nature of some parts of the area, there are good footpaths, road networks and tracks (Nur and Ayuni, 2011).…”
Section: Study Areamentioning
confidence: 99%
“…The weathered/fractured zones of the basement are where groundwater is most likely to be found. Researchers have used the resistivity approach to explore groundwater in Basement Complex (Acworth, 1987;Olurunfemi and Fasuyi, 1993;Edet and Okereke, 1997;Nur and Ayuni, 2004;Nur and Kujir, 2006;Zohdy et al, 1974;and Olasehinde, 2010). Failure rates of the borehole are highest in the basement terrain, according to experience from around the world.…”
Section: Introductionmentioning
confidence: 99%