2013
DOI: 10.1016/j.chroma.2013.01.009
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid preconcentrator/focuser module for determinations of explosive marker compounds with a micro-scale gas chromatograph

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
40
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 39 publications
(42 citation statements)
references
References 36 publications
1
40
0
Order By: Relevance
“…A Si lid (33 × 10 × 0.5 mm) was also fabricated with a linear, recessed DRIE channel, 150 μm deep × 350 μm wide, running lengthwise down the center to align directly above the sensors in the array. The linearity of the interconnection with external capillaries was an improvement over previous μCR array configurations 47,51 . The array was plugged into a socket on a carrier PCB, and the entire assembly was covered with a grounded Cu Faraday cage.…”
Section: μCr Arraymentioning
confidence: 81%
See 1 more Smart Citation
“…A Si lid (33 × 10 × 0.5 mm) was also fabricated with a linear, recessed DRIE channel, 150 μm deep × 350 μm wide, running lengthwise down the center to align directly above the sensors in the array. The linearity of the interconnection with external capillaries was an improvement over previous μCR array configurations 47,51 . The array was plugged into a socket on a carrier PCB, and the entire assembly was covered with a grounded Cu Faraday cage.…”
Section: μCr Arraymentioning
confidence: 81%
“…Members of our group have reported on a number of μGC and μGC × μGC components and systems in recent years [37][38][39][40][41][42][43][44][45][46][47][48][49][50] . We have also developed automated prototype instruments containing μGC systems for measuring low-to sub-ppb concentrations of trichloroethylene (TCE) in vapor-intrusion impacted homes 51,52 , and markers of explosives for transportation security 53,54 .…”
Section: Introductionmentioning
confidence: 99%
“…These have been successfully developed for highly-sensitive Surface Acoustic Wave sensors for hazardous targets including nerve agents and radionuclides (Grate, 2008), and for HPLC columns applied to environmental monitoring (Egorov et al, 2006;Grate et al, 2007). These polymers effectively act as a "magnet" for the explosives, whereby the nitroaromatic compound adsorbs to the surface, and the application of heat leads to thermal desorption (Camara et al, 2014;Martin et al, 2007;Serrano et al, 2013;Tiwary et al, 2016;Voiculescu et al, 2006), as shown in Figure 2. The specially designed materials studied in the literature for this purpose are usually expensive (approx.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…Besides the optimization of the adsorption-desorption parameters, the performance of the preconcentrator relies also on an optimum choice of the adsorbent material. This choice depends on the type of application and the nature of the gases to be detected [3,4]. In the case of explosives detection, we are dealing with compounds having very low vapor pressures and concomitantly high adhesion energies which require high desorption temperatures and thus large power consumption.…”
Section: Introductionmentioning
confidence: 99%