Hybrid Power Filter to Enhance Power Quality in a Medium-Voltage Distribution Network

Abstract: Abstract-This paper deals with the problem of reactive power and harmonics in a standard medium-voltage (MV) distribution network. It proposes a simple and inexpensive solution to enhance power quality when a particular connection to the high-voltage transmission network is required. It presents the design of a hybrid active filter topology connected to the MV level of a power distribution system. Its main task is to regulate a 132-kV voltage level. Reconfiguration of the power delivery network imposes new con… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
37
0
6

Year Published

2011
2011
2018
2018

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 98 publications
(43 citation statements)
references
References 22 publications
0
37
0
6
Order By: Relevance
“…However, during the negative half cycle, as long as the integrator output is greater than the reference signal, q 4 conducts and q 1 does not. When two signals are equal, the integrator becomes reset and as long as the integrator output is zero q 1 is on and q 4 is off.…”
Section: Variable Index Pulse Width Modulationmentioning
confidence: 99%
See 1 more Smart Citation
“…However, during the negative half cycle, as long as the integrator output is greater than the reference signal, q 4 conducts and q 1 does not. When two signals are equal, the integrator becomes reset and as long as the integrator output is zero q 1 is on and q 4 is off.…”
Section: Variable Index Pulse Width Modulationmentioning
confidence: 99%
“…In response to the power quality problem, IEEE 519 and IEC EN 61000-3 standards specify regulations governing harmonic compliance. Numerous active filters are introduced as effective means to meet the harmonic standards beside the passive filters that have been proposed [1][2][3][4]. The SAF has become a mature technology in recent years.…”
Section: Introductionmentioning
confidence: 99%
“…The control of harmonic perturbations by active power filters (APFs) has become a hot topic in the power engineering field. In the past two decades, active power filters have developed rapidly to suppress harmonics in the power distribution systems of 380V voltage grids [1]- [4]. But the voltage grids of many power distribution systems for making petroleum hole are 600V.…”
Section: Introductionmentioning
confidence: 99%
“…Os três valores de distorção aderidos tiveram como base [68][69][70][71] As características das cargas e das compensações reativas são as mesmas do tópico passado.…”
Section: Fonte De Tensão Harmônicaunclassified
“…As correntes da fonte conectada à barra III (laranja) foram calculadas da mesma forma, porém, as suas magnitudes foram multiplicadas por um fator que valeu 0,45. Tal fator foi necessário para adequar a distorção de tensão na barra III e nas suas proximidades a valores típicos de redes de distribuição [65][66][67][68][69][70][71].…”
Section: Compensação Reativa Dinâmica De Reativos Em Redes De Distribunclassified