2020
DOI: 10.3390/e22020178
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid Membrane Distillation and Wet Scrubber for Simultaneous Recovery of Heat and Water from Flue Gas

Abstract: Flue gas contains high amount of low-grade heat and water vapor that are attractive for recovery. This study assesses performance of a hybrid of water scrubber and membrane distillation (MD) to recover both heat and water from a simulated flue gas. The former help to condense the water vapor to form a hot liquid flow which later used as the feed for the MD unit. The system simultaneously recovers water and heat through the MD permeate. Results show that the system performance is dictated by the MD performance … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 39 publications
(41 reference statements)
0
7
0
Order By: Relevance
“…The pure water permeability coefficient, the solute permeability coefficient and the structural parameter of the applied membrane were 5.36 L m −2 h −1 bar −1 , 0.95 L m −2 h −1 and 0.265 mm, respectively as reported elsewhere [ 38 ]. In contrast, the PTFE membrane used for MD operation possess hydrophobic properties of 138° contact angle, pore size of 0.22 µm, thickness of 175 µm and 70% of membrane porosity as reported in our earlier report [ 28 ].…”
Section: Methodsmentioning
confidence: 72%
See 1 more Smart Citation
“…The pure water permeability coefficient, the solute permeability coefficient and the structural parameter of the applied membrane were 5.36 L m −2 h −1 bar −1 , 0.95 L m −2 h −1 and 0.265 mm, respectively as reported elsewhere [ 38 ]. In contrast, the PTFE membrane used for MD operation possess hydrophobic properties of 138° contact angle, pore size of 0.22 µm, thickness of 175 µm and 70% of membrane porosity as reported in our earlier report [ 28 ].…”
Section: Methodsmentioning
confidence: 72%
“…The FO unit in the hybrid FO–MD system is expected to serve as a low-cost and high-efficiency pretreatment for MD to remove the substances from feed solution that potentially cause wetting while offering a great solution to membrane fouling in MD [ 26 ], since MD is only involve in treating sole draw solutes from FO [ 27 ]. At the same time, MD also shows great potential for small-scale wastewater reclamation, decentralized systems with available waste heat source [ 2 ], as well as for waste heat recovery from the flue gas [ 28 ].…”
Section: Introductionmentioning
confidence: 99%
“…Mohd Hizami Mohd Yusoff et al intensified the membrane distillation (MD) process by combining it with a wet scrubber (WS). 72 The MD + WS system simultaneously…”
Section: Pi Technology In Other Process Industry Wastewater Purificat...mentioning
confidence: 99%
“…Mohd Hizami Mohd Yusoff et al intensified the membrane distillation (MD) process by combining it with a wet scrubber (WS). 72 The MD + WS system simultaneously recovered water and heat through the MD permeate using polytetrafluoroethylene (PTFE) as the membrane polymer. The scrubber achieved complete water and heat recovery.…”
Section: Pi Application In Textile and Other Process Industries Integ...mentioning
confidence: 99%
“…-Coupling of wet scrubber and integration with MD [67] -Cooling the gas using humidifier followed by hydrophobic membrane condenser [68,69] emergent mater.…”
Section: Other MD Applicationsmentioning
confidence: 99%