HVAC system design under peak load prediction uncertainty using multiple-criterion decision making technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
41
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 105 publications
(41 citation statements)
references
References 19 publications
0
41
0
Order By: Relevance
“…validated by the developers (e.g., Type 666 for the chiller, Type 742 for the constant speed pump in the primary chilled water loop, Type 741 for the variable speed pump in the secondary chilled water loop, Type 744 for the ventilation fan), which are the same as those in previous studies[12,[67][68][69][70][71][72]. The energy consumption of the chiller is calculated from Equations 8-12, and the energy consumptions of the pumps and fans are estimated using Equations 13 and 14 respectively[71][72][73].…”
mentioning
confidence: 89%
See 1 more Smart Citation
“…validated by the developers (e.g., Type 666 for the chiller, Type 742 for the constant speed pump in the primary chilled water loop, Type 741 for the variable speed pump in the secondary chilled water loop, Type 744 for the ventilation fan), which are the same as those in previous studies[12,[67][68][69][70][71][72]. The energy consumption of the chiller is calculated from Equations 8-12, and the energy consumptions of the pumps and fans are estimated using Equations 13 and 14 respectively[71][72][73].…”
mentioning
confidence: 89%
“…The energy consumption of the chiller is calculated from Equations 8-12, and the energy consumptions of the pumps and fans are estimated using Equations 13 and 14 respectively[71][72][73]. The key air conditioning system in TRNSYS are summarized inTable 2, more detailed descriptions of the energy consumption evaluation of the air conditioning system are available in studies[67][68][69][70][71][72].…”
mentioning
confidence: 99%
“…Secondly, the renewable energy system is sized based on the under-estimated building energy generation and over-estimated building energy consumption. As a result, the renewable energy system is commonly oversized, with unnecessarily high initial investment and a low SCR [24,25]. On the other hand, the building energy generation and consumption are vulnerable to uncertainties associated with weather, building physical properties and etc.…”
Section: Introductionmentioning
confidence: 99%
“…The case studies consider 10,000 decision scenarios (i.e., users' preferences to the design criteria). The users' preferences in practice can significantly affect the overall performance of the finally selected design option [25]. Thus, different users' preferences should be taken into consideration to ensure the robustness of the proposed method.…”
Section: Introductionmentioning
confidence: 99%
“…Two group variables [14] that associated with building dynamic cooling load can be categorized as follows:…”
Section: Description Of Improved Arx Modelmentioning
confidence: 99%