2020
DOI: 10.1093/jn/nxaa246
|View full text |Cite
|
Sign up to set email alerts
|

Human Milk Sampling Protocols Affect Estimation of Infant Lipid Intake

Abstract: Background Human milk (HM) lipid content is highly variable, and infants consume different volumes of milk. This makes precise sampling and calculation of the infant lipid intake problematic. Objectives In order to describe inaccuracies of estimates of lipid content introduced by various sampling protocols, we compared the true infant lipid intake with estimated intakes using different milk sampling protocols. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 17 publications
0
10
0
Order By: Relevance
“…Total fat increases across a breastfeed and changes throughout the day due to the relationship between fat content and the fullness of the breast [63,252]. As such sampling is problematic with one sample not being representative of either fat content or infant fat intake as illustrated by George et al [253]. Further, analysis differs according to analytical technique, with the creamatocrit method offering an attractive alternative to more complex biochemical assays [254,255] such that it could be integrated into the clinical practice, particularly in the area of preterm nutrition, to increase the energy content of milk [256].…”
Section: Lipidsmentioning
confidence: 99%
See 1 more Smart Citation
“…Total fat increases across a breastfeed and changes throughout the day due to the relationship between fat content and the fullness of the breast [63,252]. As such sampling is problematic with one sample not being representative of either fat content or infant fat intake as illustrated by George et al [253]. Further, analysis differs according to analytical technique, with the creamatocrit method offering an attractive alternative to more complex biochemical assays [254,255] such that it could be integrated into the clinical practice, particularly in the area of preterm nutrition, to increase the energy content of milk [256].…”
Section: Lipidsmentioning
confidence: 99%
“…This is consistent with our previous study that showed reductions in the proportion of capric (C10:0) and lauric acids and increases in palmitoleic and stearic acid [ 260 ] in unwell mothers and infants. Indeed it also highlights both the importance of measuring component intake [ 261 ] and with respect to total lipid employing extensive sampling [ 253 ].…”
Section: Infant Healthmentioning
confidence: 99%
“…The sum of all feeds gave the fat intake for the 24 h period on the day that milk production was assessed. Separate milk samples were collected before and after every feed for the purpose of calculating total fat intake (more accurate than using only a prefeed sample) [25].…”
Section: Calculated Intake Of Human Milk Macronutrientsmentioning
confidence: 99%
“…However, the influence of HM sample collection on macronutrient composition must be considered when utilizing HMA for clinical nutrition decisionmaking. The fat content of HM is known to vary most significantly throughout the day and within a single feed (47)(48)(49). Protein content is known to decrease over multiple weeks and has also been reported to vary throughout 24 h (11,15,50).…”
Section: Barrier 2: Collecting a Representative Samplementioning
confidence: 99%