2020
DOI: 10.1103/physrevresearch.2.022042
|View full text |Cite
|
Sign up to set email alerts
|

Huge linear magnetoresistance due to open orbits in γPtBi2

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 21 publications
(15 citation statements)
references
References 41 publications
0
15
0
Order By: Relevance
“…Resistivity measurements have been performed using the four probe AC method, with four electrical contacts made by gluing 25 µm gold wires with silver epoxy on the cleaved surface of LaRu 2 P 2 samples. For magnetoresistance measurements, we have used a cryostat with base temperature 1 K and equipped with a 20+2 T superconducting magnet [21][22][23]. Resistivity was measured using a SR 830 lock-in amplifier.…”
Section: Methodsmentioning
confidence: 99%
“…Resistivity measurements have been performed using the four probe AC method, with four electrical contacts made by gluing 25 µm gold wires with silver epoxy on the cleaved surface of LaRu 2 P 2 samples. For magnetoresistance measurements, we have used a cryostat with base temperature 1 K and equipped with a 20+2 T superconducting magnet [21][22][23]. Resistivity was measured using a SR 830 lock-in amplifier.…”
Section: Methodsmentioning
confidence: 99%
“…This emerges theoretically through a characteristic exponent exp(−W/|ωc|τ0) in Eqs. ( 5) and (6). The turnover scale B * depends on microscopic details and is given by…”
Section: Specific Modelmentioning
confidence: 99%
“…Kohler's rule may be violated in systems containing multiple bands, T -dependent anisotropy [3], a separation of lifetimes [4,5] or open orbits [6,7]. In addition, a lack of saturation in the MR can occur in perfectly charge-neutral semimetals [8].…”
Section: Introductionmentioning
confidence: 99%
“…Note that, application of MS requires material to have relatively large magnetoresistance. PtBi with a layered hexagonal crystal structure was reported to exhibit a large magnetoresistance 28 32 . Both band structures and invariant calculations suggest PtBi as a possible candidate for bulk topological metal 28 .…”
Section: Introductionmentioning
confidence: 99%
“…More recently, APRES measurement and first principle calculation detected five bands that could contribute to the TDP 33 . Magnetoresistance measurement for field up to 22T found that magnetoresistance is related to the angle between the magnetic field and the crystalline c axis 32 . In this paper, we use maximum entropy mobility spectrum analysis 34 (MEMSA) to study carrier properties of PtBi .…”
Section: Introductionmentioning
confidence: 99%