2002
DOI: 10.1016/s0042-207x(01)00468-7
|View full text |Cite
|
Sign up to set email alerts
|

Hot corrosion behavior of boiler tube materials in refuse incineration environment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
33
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 77 publications
(35 citation statements)
references
References 0 publications
1
33
0
Order By: Relevance
“…Yamada et al 14) carried out studies to evaluate the hightemperature corrosion resistance of Ni-20Cr, Ni-50Cr and Cr coated boiler tubes in actual refuse incineration plant as well as in laboratory tests. Uusitalo et al 15) and Uusitalo et al 16) have reported the use of thermal sprayed Ni/Cr coatings on ferritic and austenitic boiler steels and studied the high temperature corrosion of the coatings in various envi-ronments consisting of different compositions of Na 2 SO 4 , K 2 SO 4 , NaCl, KCl salts in oxidising as well as reducing atmospheres of mixed gases.…”
Section: Introductionmentioning
confidence: 99%
“…Yamada et al 14) carried out studies to evaluate the hightemperature corrosion resistance of Ni-20Cr, Ni-50Cr and Cr coated boiler tubes in actual refuse incineration plant as well as in laboratory tests. Uusitalo et al 15) and Uusitalo et al 16) have reported the use of thermal sprayed Ni/Cr coatings on ferritic and austenitic boiler steels and studied the high temperature corrosion of the coatings in various envi-ronments consisting of different compositions of Na 2 SO 4 , K 2 SO 4 , NaCl, KCl salts in oxidising as well as reducing atmospheres of mixed gases.…”
Section: Introductionmentioning
confidence: 99%
“…Goyal et al [121] confirm that the addition of inhibitor such as ZrO 2 to boiler environment such as Na 2 SO 4 -60% V 2 O 5 can help in decreasing the corrosion rate of superalloys at high temperature. Yamada et al [106] tested the D-gun, HVOF, and plasma sprayed 50% Ni-50% Cr alloy coating on steel and Ni based superalloys in actual refuse incineration environment. Analysis revealed the presence of chlorine, which is the main cause of hot corrosion in the coated areas.…”
Section: Remedial Measuresmentioning
confidence: 99%
“…Yamada et al [63] carried out studies to evaluate the hightemperature corrosion resistance of Ni-20Cr, Ni-50Cr and Cr coated boiler tubes in an actual refuse incineration plant as well as in laboratory tests. It was observed that a detonation sprayed Ni-50Cr coating exhibited the highest corrosion resistance in the laboratory test at 873 K among the detonation gun sprayed, plasma sprayed and HVOF sprayed coatings.…”
Section: Nickel-chromium Coatingsmentioning
confidence: 99%