1988
DOI: 10.1620/tjem.156.suppl_137
|View full text |Cite
|
Sign up to set email alerts
|

Home sleep monitor for detecting apnea episodes by nasal flow and tracheal sound recordings.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

1993
1993
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…Sef represents T-section at the constriction with its associated sound pressure source p . The value of p is 20% of the pressure calculated by (3). Similarly, p is 40% of the calculated pressure, and p is 20%, etc.…”
Section: B Acoustic Source Modelingmentioning
confidence: 91%
“…Sef represents T-section at the constriction with its associated sound pressure source p . The value of p is 20% of the pressure calculated by (3). Similarly, p is 40% of the calculated pressure, and p is 20%, etc.…”
Section: B Acoustic Source Modelingmentioning
confidence: 91%
“…The feasibility of monitoring breath sounds over the trachea to detect apneic events was perhaps first described by Krumpe and Cummiskey 11 and Cummiskey et al 12 Subsequently, Hida et al 13 reported their uncontrolled case series using tracheal sound recordings combined with airflow measures at the nose. Other studies 14,15 included investigations comparing tracheal sound records to airflow detection plus continuous pulse oximetry.…”
Section: Discussionmentioning
confidence: 99%
“…The portable home sleep monitoring system we have renovated is easier to operate and to analyse, and has more cost-saving benefits than the previous system [2], We can obtain detailed information on sleep apnea within 10 min and analysis by a host computer on the following day. However, there still remain several problems.…”
Section: Discussionmentioning
confidence: 99%
“…is burdensome, laborious, time consuming, costly and inconvenient as a screening test or epidemiological study, particularly outside of a hospital. We previously reported a portable sleep monitoring system with a casette data rec order [2], which records analog signals of nasal flow, tra cheal sound and electrocardiogram (ECG). Since this sys tem requires a play back of the casette tape by high-speed performance for analysis, it is not yet feasible for clinical purposes.…”
Section: Introductionmentioning
confidence: 99%