2022
DOI: 10.1016/j.ijleo.2022.168897
|View full text |Cite
|
Sign up to set email alerts
|

Highly sensitive SPR-based PCF bio sensor for plasma cell detection in human blood for the detection of early stage cancer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 30 publications
(13 citation statements)
references
References 36 publications
0
11
0
Order By: Relevance
“…A comparison between the proposed V-shaped cancer detection sensor with the previously reported sensors in (Sani et al 2022), (Verma, Kumar and Jindal, 2022), (Chaudhary, Kumar and Kumar, 2022), (Rajeswari and Revathi 2022), (Yasli 2021), (Jabin et al 2019), (Ayyanar et al 2018), (Mollah et al 2020), (Ramanujam et al 2019), (Jindal et al 2016), (Abdelghaffar et al 2022) and (Ramanujam et al 2019), (Singh and Prajapati 2023), (Almawgani et al 2022), (Malek et al 2022), (Yasli 2022), (Nayak 2023) is depicted in Table 6. It is evident that the sensitivity of the proposed early cancer detection biosensor is greater than the introduced biosensors in (Jabin et al 2019), (Ayyanar et al 2018), (Ramanujam et al 2019), (Jindal et al 2016), (Sani et al 2022), (Almawgani et al 2022), (Malek et al 2022), (Yasli 2022) (Nayak 2023) (Abdelghaffar et al 2022)and (Ramanujam et al 2019).…”
Section: Fabrication Tolerance Studymentioning
confidence: 99%
See 2 more Smart Citations
“…A comparison between the proposed V-shaped cancer detection sensor with the previously reported sensors in (Sani et al 2022), (Verma, Kumar and Jindal, 2022), (Chaudhary, Kumar and Kumar, 2022), (Rajeswari and Revathi 2022), (Yasli 2021), (Jabin et al 2019), (Ayyanar et al 2018), (Mollah et al 2020), (Ramanujam et al 2019), (Jindal et al 2016), (Abdelghaffar et al 2022) and (Ramanujam et al 2019), (Singh and Prajapati 2023), (Almawgani et al 2022), (Malek et al 2022), (Yasli 2022), (Nayak 2023) is depicted in Table 6. It is evident that the sensitivity of the proposed early cancer detection biosensor is greater than the introduced biosensors in (Jabin et al 2019), (Ayyanar et al 2018), (Ramanujam et al 2019), (Jindal et al 2016), (Sani et al 2022), (Almawgani et al 2022), (Malek et al 2022), (Yasli 2022) (Nayak 2023) (Abdelghaffar et al 2022)and (Ramanujam et al 2019).…”
Section: Fabrication Tolerance Studymentioning
confidence: 99%
“…Further, (Verma, Kumar and Jindal, 2022) and (Singh and Prajapati 2023) have used dual plasmonic materials with higher fabrication cost. In Addition, (Mollah et al 2020) and (Rajeswari and Revathi 2022) have used internal coating for the plasmonic material through the PCF which is a challenge for fabrication. Further, analyte infiltration will be difficult through the PCF air holes as reported in (Mollah et al 2020).…”
Section: Fabrication Tolerance Studymentioning
confidence: 99%
See 1 more Smart Citation
“…Several ways have been reported to overcome this, using surface plasmon resonance (SPR) technology based on photonic crystal fiber (PCF) will be a good technique in detecting analyte samples [1], for various applications such as in the medical world [2], food safety [3], environment and biochemistry [4]. SPR sensors are widely used in glucose sensing [5], virus detection [6], gas sensing [7], blood type detection [8], environmental sensing [9], food quality measurement [10], telemedicine [11], sensing temperature [12]- [15] and antigen-antibody interactions and other biochemical applications [13].…”
Section: Introductionmentioning
confidence: 99%
“…In the field of cancer detection, SPR sensors can be used to study the behavior of human cells, and also to analyze the change of the protein in the cell to determine if this cell is normal or cancerous (Bellassai et al 2019;Rajeswari and Revathi 2022). On the other hand, diabetes patients can beneficiate from SPR sensors, as these sensors can detect the glucose level but in a more convenient way with very high accuracy (Shen et al 2007).…”
Section: Introductionmentioning
confidence: 99%