2011
DOI: 10.1128/aem.05556-11
|View full text |Cite
|
Sign up to set email alerts
|

High-Throughput Typing Method To Identify a Non-Outbreak-Involved Legionella pneumophila Strain Colonizing the Entire Water Supply System in the Town of Rennes, France

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
41
2

Year Published

2012
2012
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(44 citation statements)
references
References 35 publications
0
41
2
Order By: Relevance
“…This approach would be cost-effective, since in our laboratory, the re-agents and sequencing costs for the characterization of one strain by means of recA sequence for species identification plus MLVA-10 were 36 euros compared to 112 euros for MLST analysis, with comparable hands-on time. Besides, the MLVA-10 scheme could easily be automated using fluorescent primers and a single multiplex PCR (31). Capillary electrophoresis would allow automatic size measurement of the PCR products and thus increase the accuracy of repeat number determination, as described for other bacterial species (31)(32)(33).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This approach would be cost-effective, since in our laboratory, the re-agents and sequencing costs for the characterization of one strain by means of recA sequence for species identification plus MLVA-10 were 36 euros compared to 112 euros for MLST analysis, with comparable hands-on time. Besides, the MLVA-10 scheme could easily be automated using fluorescent primers and a single multiplex PCR (31). Capillary electrophoresis would allow automatic size measurement of the PCR products and thus increase the accuracy of repeat number determination, as described for other bacterial species (31)(32)(33).…”
Section: Discussionmentioning
confidence: 99%
“…Besides, the MLVA-10 scheme could easily be automated using fluorescent primers and a single multiplex PCR (31). Capillary electrophoresis would allow automatic size measurement of the PCR products and thus increase the accuracy of repeat number determination, as described for other bacterial species (31)(32)(33). Furthermore, some potentially informative VNTR markers that were ruled out from the present scheme due to short repeats (Ͻ15 bp) could be included to constitute a second panel with high discriminatory power, as has been proposed for other bacteria (34).…”
Section: Discussionmentioning
confidence: 99%
“…The MLVA used for Mycobacterium tuberculosis [9] [10]. Alternatively, the assays can be set up locally, with no need to buy kits, since all the necessary information is published [10][11][12]. MLVA is also in routine use for Streptococcus pneumoniae, with more than 1,000 genotypes publicly accessible from the the Robert Picqué Military Hospital in Bordeaux [13] and for Acinetobacter baumanii [14].…”
Section: Francementioning
confidence: 99%
“…(NA) and STTR3 (211) and different combinations of the variable loci STTR5 (11,12,13) and STTR6 (9,10), where paranthesised numbers denote allele sizes and NA (no amplification) indicates negative PCR amplification, as previously described [2].…”
Section: Denmarkmentioning
confidence: 99%
See 1 more Smart Citation