High-temperature gradient HPLC for the separation of polyethylene–polypropylene blends

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
50
0

Year Published

2007
2007
2015
2015

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 60 publications
(52 citation statements)
references
References 36 publications
(35 reference statements)
2
50
0
Order By: Relevance
“…For comparison, a separation of PE from PP with molar mass below about 20 kg/mol was not possible using precipitation-redissolution chromatography with EGMBE as the mobile phase. 36,37 We note that oligomers of PE and PP with smaller molar mass evaporate at 260 C in the ELSD and therefore do not yield a detector response.…”
Section: Resultsmentioning
confidence: 92%
See 2 more Smart Citations
“…For comparison, a separation of PE from PP with molar mass below about 20 kg/mol was not possible using precipitation-redissolution chromatography with EGMBE as the mobile phase. 36,37 We note that oligomers of PE and PP with smaller molar mass evaporate at 260 C in the ELSD and therefore do not yield a detector response.…”
Section: Resultsmentioning
confidence: 92%
“…The group of Prof. H. Pasch (present address: University of Stellenbosch, Stellenbosch, South Africa) in Darmstadt has recently published the first HPLC procedures for the separation of PE and PP. [36][37][38][39][40][41][42][43] PE or PP were selectively adsorbed in the zeolites [40][41][42][43] or HPLC separation has been based on selective precipitation of PE. 36,38 Lehtinen und Paukerri 44 found that ethylene glycol monobutyl ether (EGMBE) dissolves isotactic polypropylene (iPP) but not linear PE.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…21 To highlight this new advance, results using the silica column system designed by Heinz et al are compared against new data generated using the graphitic carbon column. 18 Previous results with a graphitic carbon column from Macko et al are also compared to the current work. 19,20 …”
Section: Introductionmentioning
confidence: 75%
“…Lehtinen and Paukkeri found that ethylene glycol monobutyl ether (EGMBE) is a good solvent for isotactic PP but a nonsolvent for linear PE [62]. This observation forms the basis for the HT HPLC separation of isotactic PP from linear PE using EGMBE as eluent [63,64]. The column used by Macko et al…”
Section: Chromatographic System Based On the Precipitation-dissolutiomentioning
confidence: 99%