2008
DOI: 10.1007/s10765-007-0356-y
|View full text |Cite
|
Sign up to set email alerts
|

High-Temperature Fixed-Point Facilities for Improved Thermocouple Calibration—Euromet Project 857

Abstract: LNE, NPL, and PTB decided in 2005 to join their research efforts in the framework of Euromet Project 857 with the aim of reducing the calibration uncertainty of noble metal and other high-temperature thermocouples by at least a factor of two. This ambitious target will be met through the development and implementation of robust high-temperature fixed points based on metal-carbon eutectic technology. The Euromet project is structured around five work packages and ensures good and efficient cooperation between … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
25
0
1

Year Published

2008
2008
2013
2013

Publication Types

Select...
7
1

Relationship

4
4

Authors

Journals

citations
Cited by 27 publications
(27 citation statements)
references
References 10 publications
(13 reference statements)
1
25
0
1
Order By: Relevance
“…To confirm and improve the performance of Co-C and Pd-C eutectic points for thermocouple calibration, comparisons of Co-C and Pd-C eutectic points were planned in the framework of the Euramet 857 project, involving three EU laboratories (LNECnam, PTB, and NPL) and one non-EU laboratory (NMIJ) [9]. At first, the comparison of the Co-C eutectic point was conducted.…”
Section: Introductionmentioning
confidence: 99%
“…To confirm and improve the performance of Co-C and Pd-C eutectic points for thermocouple calibration, comparisons of Co-C and Pd-C eutectic points were planned in the framework of the Euramet 857 project, involving three EU laboratories (LNECnam, PTB, and NPL) and one non-EU laboratory (NMIJ) [9]. At first, the comparison of the Co-C eutectic point was conducted.…”
Section: Introductionmentioning
confidence: 99%
“…C'est dans cette optique que nous travaillons depuis une dizaine d'années au développement de thermocouples Pt/Pd de très haute stabilité et de points fixes à haute température adaptés à leur étalonnage jusqu'à 1500 °C [26]. Au-delà de cette température, d'autres thermocouples peuvent être utilisés (W/Re, Ir/Ir-Rh, Pt-Rh/Pt-Rh..) mais leur stabilité aux plus hautes températures est insuffisante, rendant encore plus indispensable la disponibilité de références de température qui permettraient leur étalonnage et la correction de leur dérive en cours d'utilisation.…”
Section: Thermocouples Et Méthodes D'autovalidationunclassified
“…Cu at 1084.62 • C is the highest conventional FP; for this reason, in the last years there has been significant research in thermocouple calibrations in metal-carbon (M-C) fixed points up to 1550 • C [1][2][3][4]. However, the comparison method is an alternative to M-C fixed points that could be used to calibrate thermocouples to 1600 • C [5,6].…”
Section: Introductionmentioning