High-speed non-unit transmission line protection using single-phase measurements and an adaptive wavelet: zone detection and fault classification

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
13
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 33 publications
(13 citation statements)
references
References 11 publications
0
13
0
Order By: Relevance
“…The discrimination components can be derived as follows: (14) where is a preset threshold; and ( , 1, 2, 3) is a logical value that will be used as a discriminant component for faulted phase selection. Fig.…”
Section: B Classification Indexmentioning
confidence: 99%
See 1 more Smart Citation
“…The discrimination components can be derived as follows: (14) where is a preset threshold; and ( , 1, 2, 3) is a logical value that will be used as a discriminant component for faulted phase selection. Fig.…”
Section: B Classification Indexmentioning
confidence: 99%
“…A novel WT-based technique for phase selection is presented in [10], and the online applications of WT to power system relaying are reported in [11]. The adaptive wavelet algorithm is proposed for feature detection in [12], based on which two methods that use single-phase measurement are presented to classify faults on transmission lines [13], [14]. In these two papers, Bayesian linear discrimination analysis is employed to process the data extracted by WT for fault classification.…”
mentioning
confidence: 99%
“…Furthermore, time domain methods to extract the travelling wave from the post-fault voltage and current are prone to noise. The wavelet transform was applied to extract travelling waves [16,[19][20][21][22][23] to effectively overcome difficulties mentioned above. As the wavelet transform can provide excellent localization both in the frequency domain and in the time domain, it is found to be a useful signal processing tool to extract travelling waves.…”
Section: Introductionmentioning
confidence: 99%
“…differential, or pilot protection) involving total protection coverage of the transmission lines with the provision of high cost communication channels installations linking end sources, and the non-unit protection systems ( e.g. distance relay) with partial line coverage protection schemes of HVTL [12]- [14]. This necessitate the need for a high-speed, low cost, and reliable unit protection scheme for the entire integrated WFG-HVTL protection scheme.…”
mentioning
confidence: 99%