High-speed multi-channel system for solar simulator irradiance non-uniformity measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0
2

Year Published

2017
2017
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 4 publications
0
6
0
2
Order By: Relevance
“…This was reasonable because the size of the test area was larger using the same light source. The light intensity around the test area would decrease the non-uniformity of solar simulator as [1], [2], [10], [14], and [28]. However, the experimental results were shown that the array detector scanning system measurements were more reliable because each measurement result in the same test-area were %uncertainty in average of 1.41% lower than that of the single detector (5.79%) significantly.…”
Section: The Analysis Of the Non-uniformity Of Irradiancementioning
confidence: 95%
“…This was reasonable because the size of the test area was larger using the same light source. The light intensity around the test area would decrease the non-uniformity of solar simulator as [1], [2], [10], [14], and [28]. However, the experimental results were shown that the array detector scanning system measurements were more reliable because each measurement result in the same test-area were %uncertainty in average of 1.41% lower than that of the single detector (5.79%) significantly.…”
Section: The Analysis Of the Non-uniformity Of Irradiancementioning
confidence: 95%
“…Data analysis was done by Specwin Pro software with a spectral mismatch as referred to the IEC 60904-9 standard [4]. The authors had developed a custom measurement device of non-uniformity for the proposed solar simulator following the studies of [19] and [20]. Ten of the monocrystalline silicon solar cells (dimension of 30 mm × 25 mm) were applied to detect the irradiance of the solar simulator (Figure 2(b)).…”
Section: E Led Power Sourcesmentioning
confidence: 99%
“…Several reasons can cause the irradiance measurement error. The solar cell output coefficient is related to the conversion efficiency, area, and incident angle of ten cells used as the irradiance sensor [20]. Other errors are the shunt resistance error in the circuit of Figure 2(a) and the offset from the op-amp of I/V converter modules.…”
Section: B Led Solar Simulator Prototype Non-uniformity Of Irradiancementioning
confidence: 99%
“…Solar simulators are often used for the indoor characterisation of photovoltaic cells [1][2][3]. This is due to the varying outdoor conditions [4].…”
Section: Introductionmentioning
confidence: 99%