2020
DOI: 10.3390/ijms21124287
|View full text |Cite
|
Sign up to set email alerts
|

High-Speed Atomic Force Microscopy Reveals the Structural Dynamics of the Amyloid-β and Amylin Aggregation Pathways

Abstract: Individual Alzheimer’s disease (AD) patients have been shown to have structurally distinct amyloid-β (Aβ) aggregates, including fibrils, in their brain. These findings suggest the possibility of a relationship between AD progression and Aβ fibril structures. Thus, the characterization of the structural dynamics of Aβ could aid the development of novel therapeutic strategies and diagnosis. Protein structure and dynamics have typically been studied separately. Most of the commonly used biophysical approaches are… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 30 publications
(17 citation statements)
references
References 177 publications
(345 reference statements)
0
17
0
Order By: Relevance
“…A sample–scanning type of HS‐AFM was operated in the amplitude modulation–tapping mode with a BL‐AC10DS‐A2 cantilever (Olympus Corp.) (Ando et al, 2001; Sahoo et al, 2019; Uchihashi et al, 2012; Watanabe‐Nakayama et al, 2016, 2020). The cantilever probes were prepared at the top of the cantilevers by electron‐beam deposition using the scanning electron microscope mode of ELS‐7500, which is an electron lithography system (Elionix Inc.).…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…A sample–scanning type of HS‐AFM was operated in the amplitude modulation–tapping mode with a BL‐AC10DS‐A2 cantilever (Olympus Corp.) (Ando et al, 2001; Sahoo et al, 2019; Uchihashi et al, 2012; Watanabe‐Nakayama et al, 2016, 2020). The cantilever probes were prepared at the top of the cantilevers by electron‐beam deposition using the scanning electron microscope mode of ELS‐7500, which is an electron lithography system (Elionix Inc.).…”
Section: Methodsmentioning
confidence: 99%
“…The results of both the elongation speed of Aβ42 aggregates in HS‐AFM and the length of Aβ aggregates with fibril‐like structures in EM images were not normally distributed, and we used Brunner–Munzel tests to evaluate the statistical significance of the HS‐AFM datasets without assuming normal distribution and equal variance, as previously reported (Watanabe‐Nakayama et al, 2016, 2020). These tests were performed using a R software version 3.6.2.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations