High-resolution inelastic x-ray scattering at the high energy density scientific instrument at the European X-Ray Free-Electron Laser

Abstract: ARTICLES YOU MAY BE INTERESTED INDemonstration of an x-ray Raman spectroscopy setup to study warm dense carbon at the high energy density instrument of European XFEL

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 23 publications
(12 citation statements)
references
References 53 publications
0
12
0
Order By: Relevance
“…The second pair of the Si( 111)-monochromator can be replaced with a Si(533) channel-cut crystal, yielding a bandwidth of ÁE/E ' 4 Â 10 À6 at a fixed photon energy of 7494 eV. More details are given by Wollenweber et al (2021). Both configurations provide zero offset between the incident and the monochromated beam.…”
Section: Monochromatorsmentioning
confidence: 99%
See 2 more Smart Citations
“…The second pair of the Si( 111)-monochromator can be replaced with a Si(533) channel-cut crystal, yielding a bandwidth of ÁE/E ' 4 Â 10 À6 at a fixed photon energy of 7494 eV. More details are given by Wollenweber et al (2021). Both configurations provide zero offset between the incident and the monochromated beam.…”
Section: Monochromatorsmentioning
confidence: 99%
“…As shown in Fig. 18, this is sufficient to resolve inelastic X-ray scattering from phonons in solids, or ion-acoustic waves in plasmas (Wollenweber et al, 2021;Descamps et al, 2020).…”
Section: Interaction Chambermentioning
confidence: 99%
See 1 more Smart Citation
“…namic experiments: at the IXS commissioning experiment of the High Energy Density (HED) end-station of the EuXFEL, the instrument function was on the order of 50 meV 97 -this has been and will continue to be further improved upon in the future at both the EuXFEL and LCLS. While the influence of the instrument function on the scattering signal is in principle deconvolvable, shot noise poses a limit due to finite integration time at experiments.…”
Section: B Qes and Energy Resolutionmentioning
confidence: 99%
“…As noted above, FELs have an enormous peak spectral brightness. Indeed, recent work on both the Linac Coherent Light Source (LCLS) 95 and at the European XFEL (EuXFEL) 96,97 has demonstrated inelastic scattering from static, unshocked samples of almost perfect diamond single crystals. The temperature of samples at both ambient and elevated levels could be determined with an error of less than 8%.…”
Section: Introductionmentioning
confidence: 99%