2017
DOI: 10.1038/s41598-017-04000-4
|View full text |Cite
|
Sign up to set email alerts
|

High-resolution imaging of a cell-attached nanointerface using a gold-nanoparticle two-dimensional sheet

Abstract: This paper proposes a simple, effective, non-scanning method for the visualization of a cell-attached nanointerface. The method uses localized surface plasmon resonance (LSPR) excited homogeneously on a two-dimensional (2D) self-assembled gold-nanoparticle sheet. The LSPR of the gold-nanoparticle sheet provides high-contrast interfacial images due to the confined light within a region a few tens of nanometers from the particles and the enhancement of fluorescence. Test experiments on rat basophilic leukemia (R… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
43
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 39 publications
(45 citation statements)
references
References 54 publications
2
43
0
Order By: Relevance
“…Rat basophilic leukaemia (RBL-2H3) cells were cultured in Roswell Park Memorial Institute (RPMI) 1640 medium supplemented with 10% foetal calf serum (FCS), 100 U/mL penicillin, and 100 μg/mL streptomycin [ 6 ]. The day before the experiment, RBL-2H3 cells were harvested using trypsin.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Rat basophilic leukaemia (RBL-2H3) cells were cultured in Roswell Park Memorial Institute (RPMI) 1640 medium supplemented with 10% foetal calf serum (FCS), 100 U/mL penicillin, and 100 μg/mL streptomycin [ 6 ]. The day before the experiment, RBL-2H3 cells were harvested using trypsin.…”
Section: Methodsmentioning
confidence: 99%
“…The RBL-2H3 cells in RPMI 1640 medium were then placed into the well and cultured for the indicated time (1 or 2 hours or overnight) in a CO 2 incubator (4% CO 2 concentration) at 37°C. The detailed procedure was described in our previous paper [ 6 ].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Although the detection limit of a confocal laser scanning microscope in z direction is known to be approx. 500 nm [9], some holographic microscopes can observe almost 30 m in depth from the cellular top surface. Taking advantage of these techniques, the cell-labeling nanomaterials can be utilized for immunoassay to diagnose early stage cancer in the visible light region.…”
Section: Introductionmentioning
confidence: 99%