Image Sensing Technologies: Materials, Devices, Systems, and Applications V 2018
DOI: 10.1117/12.2304835
|View full text |Cite
|
Sign up to set email alerts
|

High resolution 3D imaging of integrated circuits by x-ray ptychography

Abstract: Significant advances in lithography and chip manufacturing in recent years have resulted in new challenges in metrology of electronic microdevices. Manufacturing process for the 10 nm node is already available and in combination with complex three-dimensional structured interconnections, there is a lack of methods for verification that the final products correspond to the original specifications. X-ray ptycho-tomography is a locally nondestructive imaging method that could potentially help to fill the gap betw… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 49 publications
0
6
0
Order By: Relevance
“…The missing requirements for such studies are the ability to electrically contact the prepared samples and a different scheme for the ptychographic scan. The first requirement is easily overcome by a laminographic stage [53,54], suitable for planar devices and which does not require milling to micron size. The second requirement is simply met by placing the sample closer to the focus point, so that the measured XBIC/XBIV map can have a resolution closer to the focus size.…”
Section: E Outlookmentioning
confidence: 99%
“…The missing requirements for such studies are the ability to electrically contact the prepared samples and a different scheme for the ptychographic scan. The first requirement is easily overcome by a laminographic stage [53,54], suitable for planar devices and which does not require milling to micron size. The second requirement is simply met by placing the sample closer to the focus point, so that the measured XBIC/XBIV map can have a resolution closer to the focus size.…”
Section: E Outlookmentioning
confidence: 99%
“…With this approach, it can be determined which contacts are really connected and which are just fake. Such advanced cross-sectioning is achievable with FIB milling or with X-rays [7,41,42,43].…”
Section: Cell Camouflagingmentioning
confidence: 99%
“…Lately, X-ray has become a serious technology used in the observation of advanced chips [27], [28], [29]. As chips are turning into unimaginably complex devices, the classic method of invasive reverse engineering is becoming harder to be successfully performed.…”
Section: Active Defense Against X-ray Observation Techniquementioning
confidence: 99%
“…With this approach, it can be determined which contacts are actually connected and which ones are just fake. Such advanced cross-sectioning is achievable with FIB milling or with X-rays [30], [51], [28], [27].…”
Section: Cell Camouflagingmentioning
confidence: 99%