2001
DOI: 10.1292/jvms.63.407
|View full text |Cite
|
Sign up to set email alerts
|

High Plasma Estradiol-17.BETA. Levels in Dogs with Benign Prostatic Hyperplasia and Azoospermia.

Abstract: ABSTRACT. The semen quality of 22 dogs (4 to 7 years old) with benign prostatic hyperplasia (BPH) was examined at the hospital of our university, and 4 of the 22 BPH dogs were diagnosed as azoospermic. The mean peripheral plasma estradiol-17β (E 2 ) level (17.3 pg/ ml) of the 18 BPH dogs with spermatogenic function was higher than that of 5 normal male dogs and their mean T level (1.7 ng/ml) was lower. The mean E 2 level (27.3 pg/ml) of the 4 BPH dogs with azoospermia was significantly higher than the value in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
4
0

Year Published

2003
2003
2020
2020

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 25 publications
0
4
0
Order By: Relevance
“…Tubes were immediately centrifuged at 1,500×g for 10 min and serum was drawn-off and stored in microtubes at − 20 °C until analysis. www.nature.com/scientificreports/ Hormonal assays were performed with the use of commercial radioimmunoassay kits for quantitative measurement of testosterone and estrogen (Beckman Coulter®), previously validated for dogs 51,52 , and competitive ELISA kits for dihydrotestosterone assay 53 , previously validated for dog. For estradiol, the intra-assay coefficients were 7.15% (high intra-assay) and 3.45% (low intra-assay) and the limit detection was 1.12 pg/mL.…”
Section: Methodsmentioning
confidence: 99%
“…Tubes were immediately centrifuged at 1,500×g for 10 min and serum was drawn-off and stored in microtubes at − 20 °C until analysis. www.nature.com/scientificreports/ Hormonal assays were performed with the use of commercial radioimmunoassay kits for quantitative measurement of testosterone and estrogen (Beckman Coulter®), previously validated for dogs 51,52 , and competitive ELISA kits for dihydrotestosterone assay 53 , previously validated for dog. For estradiol, the intra-assay coefficients were 7.15% (high intra-assay) and 3.45% (low intra-assay) and the limit detection was 1.12 pg/mL.…”
Section: Methodsmentioning
confidence: 99%
“…Testosterone and estrogen concentration was measured using a commercial radiomunoassay kit (BECKMAN Coulter Company IM-1841 / IM-1119-Immunotech, Prague, Czech Republic and BECKMAN Coulter Company IM-1841 / DSL4800-Immunotech, Prague, Czech Republic, respectively), both previously validated for dogs [13,27] For dihydrotestosterone, competitive ELISA kit (BECKMAN, Active1 DSL9600i-Immunotech-, Prague, Czech Republic) was used [28]. The limit detection for the testosterone assay was 0.01 ng/mL and the intraassay coefficient of variation was 4.52%.…”
Section: Hormonal Profile Of Testosterone Estrogen and Dihydrotestosmentioning
confidence: 99%
“…In the testes of many species [2,17], including dogs [3], the E 2 -secreting cells are the Sertoli cells and/or the Leydig cells [13,20]. In men [6,19] abnormally increased testicular E 2 production causes spermatogenic dysfunction, and long-term E 2 administration has been shown to inhibit spermatogenesis in dogs [8,15]. Aromatase inhibitor (AI) blocks the aromatization of androgen to E 2 by inhibiting aromatase enzyme activity [1,18], and AI has been reported to be effective in treating spermatogenic dysfunction in men with high plasma E 2 levels [4].…”
mentioning
confidence: 99%
“…Peripheral blood samples were collected from the two azoospermic dogs at the same time as the semen collections. Plasma E 2 and T levels were measured by the radioimmunoassay described previously [8]. The plasma E 2 levels of the two dogs (21 and 22 pg/ml, respectively) were higher than those of two normal Beagles (Dog A and Dog B, as controls)(8.1 and 12.3 pg/ml, respectively), aged 2 and 4 years, and their plasma T levels (1.2 and 1.4 ng/ml) were lower ( Table 2).…”
mentioning
confidence: 99%