2005
DOI: 10.1109/tmtt.2005.848832
|View full text |Cite
|
Sign up to set email alerts
|

High performances of shielded LTCC vertical transitions from DC up to 50 GHz

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
27
0
1

Year Published

2007
2007
2022
2022

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 76 publications
(28 citation statements)
references
References 9 publications
0
27
0
1
Order By: Relevance
“…The electromagnetic (EM) simulators use Maxwell equations to compute the response of a structure from its physical geometry. It can be applied to study complex 3D structures composed of linear and isotropic or anisotropic media [8]. This analysis method has great accuracy and presents attractive advantages to minimize computation time and provides better accurate results [9].…”
Section: Design Toolmentioning
confidence: 99%
“…The electromagnetic (EM) simulators use Maxwell equations to compute the response of a structure from its physical geometry. It can be applied to study complex 3D structures composed of linear and isotropic or anisotropic media [8]. This analysis method has great accuracy and presents attractive advantages to minimize computation time and provides better accurate results [9].…”
Section: Design Toolmentioning
confidence: 99%
“…Generally, vias are highly utilized in vertical interconnection structures of high-density system-on-package substrates [23][24][25][26]. Field discontinuity may deteriorate the frequency response of filters when signals travel through vias, since the induced parasitic inductance behaves akin to a low-pass filter, attenuating high-frequency components.…”
Section: Fold-back Structurementioning
confidence: 99%
“…The distance between centre line of the aperture and circle centre d; the length of the stub l (calculated from centre line of the aperture); /4), h 0 = 2 mm, w 0 = 0.2 mm, R 0 = 1.6 mm, the transition structure was modeled with solid wall firstly and then the solid wall was replaced by vias-array under the guidelines of references [8][9][10][11], Some applications of SICC can be found in references [12][13][14], some important design guidelines can be found in [15][16][17][18][19]. The radius of the cavity R and the gap location d were two key parameters in designing of the transition structure; the R can be calculated with (3), and the parameter d was approximately λ g /4 ; the width of the microstrip lines were calculated to guarantee a 50 Ω impedance.…”
Section: Design Of the Sicc Transitionmentioning
confidence: 99%