2017
DOI: 10.1016/j.chroma.2016.12.080
|View full text |Cite
|
Sign up to set email alerts
|

High performance liquid chromatography analysis of 100-nm liposomal nanoparticles using polymer-coated, silica monolithic columns with aqueous mobile phase

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 25 publications
(12 citation statements)
references
References 36 publications
0
12
0
Order By: Relevance
“…26) It is appropriate that albumin fluorescence changed within 30 min, because it has been reported that corona was formed just after intravenous administration of the liposomal drug. 8,9) Therefore, it is important to evaluate doxorubicin release from DOXIL that formed corona, and fluorescence spectrometry is a useful technique for this evaluation.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…26) It is appropriate that albumin fluorescence changed within 30 min, because it has been reported that corona was formed just after intravenous administration of the liposomal drug. 8,9) Therefore, it is important to evaluate doxorubicin release from DOXIL that formed corona, and fluorescence spectrometry is a useful technique for this evaluation.…”
Section: Resultsmentioning
confidence: 99%
“…Hence, many previous studies have been conducted to study the dynamics and efficacy of the protein-DOXIL complex. [7][8][9] However, popular analytical methods (ultracentrifugation, gel electrophoresis, and circular dichroism) are laborious and time-consuming. [10][11][12] The development of a simple and easy monitoring method for doxorubicin release in biosamples is strongly demanded.…”
Section: Introductionmentioning
confidence: 99%
“…Separation of DOXIL and Doxorubicin Using the GMACoated Column We previously reported that a GMA-coated column successfully separated DOXIL and doxorubicin within 2 min under aqueous conditions, 11) and therefore, we selected the GMA-coated column for use in this study. As shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…11) Monolithic silica gel (3 mm i.d.×30 mm long) having a through pore size of 2 µm, mesopore size of 18 nm, and surface area of 200 m 2 /g was obtained from GL Sciences Inc. (Tokyo, Japan). The monolithic silica gel was modified with a spacer, N-(3-triethoxysilylpropyl) methacrylamide that was prepared from a mixture of 3-aminopropyltriethoxysilane and triethylamine in toluene and addition of methacryloyl chloride in toluene dropwise under stirring for 0.5 h at 0°C.…”
Section: Methodsmentioning
confidence: 99%
“…Nevertheless, those methods imply a priori characterization of the stability of encapsulated drugs during analysis to ensure that leakage does not occur. Moreover, adsorption of nanoparticles to a conventional stationary phase often precludes hydrodynamic separations [21,22].…”
Section: Introductionmentioning
confidence: 99%