High-performance liquid chromatographic determination of urinary free catecholamines with electrochemical detection after prepurification on immobilized boric acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

1984
1984
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(4 citation statements)
references
References 17 publications
0
4
0
Order By: Relevance
“…One milliliter of this was put into autosampler vials and mixed with 20 μl 5 M HCl. For injection of the eluate into the HPLC system the flow rate was adjusted to 0.8 ml/m and the detection range of the electrochemical detector was set at 610 mV (Intra-assay -precision <5%, inter-assay-precision <6%) [19,20].…”
Section: Methodsmentioning
confidence: 99%
“…One milliliter of this was put into autosampler vials and mixed with 20 μl 5 M HCl. For injection of the eluate into the HPLC system the flow rate was adjusted to 0.8 ml/m and the detection range of the electrochemical detector was set at 610 mV (Intra-assay -precision <5%, inter-assay-precision <6%) [19,20].…”
Section: Methodsmentioning
confidence: 99%
“…Since the occurrence of nucleosides in physiological fluids turned out to be predicative for the diagnosis of pathobiochemical processes, the on-line System is the method of choice, äs it is particularly suitable for automatization and applicable for routine clinical analysis. As affinity chromatography on boronic acid-functionalized polymers is also well known for the pre-purification of catecholamines in physiological fluids (34)(35)(36)(37)(38), for the Separation of ribonucleosides and ribonucleotides from the corresponding deoxy-compounds (22,39,40), the Separation of RNA from DNA (41,42) and the Separation of queuine-containing tRNA from non-queuine tRNA (41) or aminoacyl-tRNA from uncharged tRNA (41,42) the use of boronate HPLAC in combination with the presented column switching technique offers a wide ränge of application.…”
Section: Discussionmentioning
confidence: 99%
“…Various analytical techniques for CAs analysis have been reported. Reverse-phase liquid chromatography (RPLC) using C18 columns hyphenated to different detection systems, including mass spectrometry (MS) [21][22][23], electrochemical detection (ECD) [24][25][26][27][28], and fluorescence detection [29] has been widely applied. However, due to the non-polar character of C18 phases and the high polarity of the CAs, derivatization steps, as well as ion pair additives are often considered.…”
Section: Introductionmentioning
confidence: 99%