High-performance liquid chromatographic assay with ultraviolet detection for quantification of dihydrofluorouracil in human lymphocytes: application to measurement of dihydropyrimidine dehydrogenase activity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0
1

Year Published

2005
2005
2020
2020

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 21 publications
(15 citation statements)
references
References 12 publications
0
14
0
1
Order By: Relevance
“…According to the recently published results from Remaud et al [18], plasmas were immediately separated by centrifugation at +4 • C and stored at −70 • C, in order to avoid changes in U concentration. PBMC DPD activity was measured according to the method of Johnson et al [8] modified by Deporte et al [9]. PBMC cells were isolated from 15 mL heparinized anticoagulant blood.…”
Section: Patients Plasma Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…According to the recently published results from Remaud et al [18], plasmas were immediately separated by centrifugation at +4 • C and stored at −70 • C, in order to avoid changes in U concentration. PBMC DPD activity was measured according to the method of Johnson et al [8] modified by Deporte et al [9]. PBMC cells were isolated from 15 mL heparinized anticoagulant blood.…”
Section: Patients Plasma Analysismentioning
confidence: 99%
“…Direct methods are based on the determination of the precise DPD enzymatic activity in PBMC [8,9]. These methods require PBMC isolation and high-performance liquid chromatography (HPLC) analysis of 5,6-dihydrofluorouracil (5-FUH2) formed from 5-FU, making the procedure timeconsuming and labor-intensive.…”
Section: Introductionmentioning
confidence: 99%
“…As a result, the HPLC-MS/MS based assay allows for a short run time and high precision and accuracy. The analysis time of the HPLC-MS/MS assay is considerably shorter than that of HPLC-ultraviolet procedures and those using radiolabeled substrates (4,6,7 ). In addition, the detection limit of the HPLC-MS/MS assay is 5 times lower than that of the reversed-phase HPLC-ultraviolet procedure, in which the product 5-fluorodihydrouracil is detected at 205 nm (4 ).…”
Section: © 2007 American Association For Clinical Chemistrymentioning
confidence: 99%
“…3) une approche biochimique permettant la mesure de l'activité enzymatique de la DPD leucocytaire a été développée [4,10,20] ; 4) une approche pharmacologique par dosage de l'uracile et/ou de la thymine plasmatique ou urinaire [1] ; 5) une approche pharmacologique par dosage plasmatique simultané de l'uracile et du dihydrouracile endogènes par Chromatographie Liquide à Haute Performance (CLHP) ou par Chromatographie Liquide couplée à la Spectrométrie de Masse en tandem (LC/MS-MS) afin d'établir le rapport UH 2 /U, reflet de l'activité globale de la DPD [13,14] ; 6) une adaptation individuelle de la dose de 5-FU par suivi pharmacocinétique [13,28].…”
Section: Le Gène De La Dpdunclassified