2010
DOI: 10.1016/j.snb.2010.05.067
|View full text |Cite
|
Sign up to set email alerts
|

High-performance compact SPR sensor for multi-analyte sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
28
0
1

Year Published

2011
2011
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(32 citation statements)
references
References 13 publications
2
28
0
1
Order By: Relevance
“…Similar compact SPR sensors based on a gold-coated grating coupled system with a much greater number of channels have been developed. [7][8][9] The sensitivity resolutions of these SPR sensors were almost at the same level as the SPR sensor reported by Piliarik et al Dostálek et al reported a method to prepare an array of gratings for an SPR sensor chip with multi-sensing points. 10 In their reports, an interference pattern generated from two coherent lights was used to prepare a master grating; its pattern was replicated to an elastomer stamp.…”
Section: Introductionsupporting
confidence: 58%
See 1 more Smart Citation
“…Similar compact SPR sensors based on a gold-coated grating coupled system with a much greater number of channels have been developed. [7][8][9] The sensitivity resolutions of these SPR sensors were almost at the same level as the SPR sensor reported by Piliarik et al Dostálek et al reported a method to prepare an array of gratings for an SPR sensor chip with multi-sensing points. 10 In their reports, an interference pattern generated from two coherent lights was used to prepare a master grating; its pattern was replicated to an elastomer stamp.…”
Section: Introductionsupporting
confidence: 58%
“…In the case of (1), an SPR sensor chip with an Au layer, which was prepared by depositing Au on a substrate with a grating structure, was assembled into a flow cell having multi-channels, and the reflected light was monitored by a 2-dimension CCD or CMOS sensor. [6][7][8][9] For example, Piliarik et al 6 developed a compact SPR sensor based on a gold-coated grating having 4 channels, and reported that its sensitivity resolution was ca. 3 × 10 -7 RIU.…”
Section: Introductionmentioning
confidence: 99%
“…Homola’s group has presented simple and compact prism-based SPR sensors with high performance. 87,88 However, performing transmission-mode spectroscopy (e.g. using nanohole arrays) in collinear setup offers some practical advantages, since it is more forgiving to a sample misalignment or tilt compared with the Kretschmann setup.…”
Section: Plasmon Spectroscopy For High-resolution Biosensingmentioning
confidence: 99%
“…The parallel and precise sample delivery capability in microfluidics enables the multiplexed detection . For example, Vala et al have demonstrated a compact SPR sensor that is capable of simultaneous detection of up to ten types of analytes based on angular interrogation of SPR on an Au‐coated diffraction grating contained in a disposable sensor cartridge with ten independent fluidic channels ( Figure ) . The sensor prototype has a detection limit of below 1 nM for short oligonucleotides.…”
Section: Microfluidics‐enhanced Plasmonic Devicesmentioning
confidence: 99%