2016
DOI: 10.1109/tpel.2015.2411858
|View full text |Cite
|
Sign up to set email alerts
|

High-Frequency-Link-Based Grid-Tied PV System With Small DC-Link Capacitor and Low-Frequency Ripple-Free Maximum Power Point Tracking

Abstract: to 2008, he was a NSERC Postgraduate (Doctor) scholar at the University of New Brunswick. Since 2009, he has been with Siemens Corporate Technology in USA as a power electronics manager. His current research interests include multilevel topologies and controls for utility and industry applications.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
76
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 170 publications
(76 citation statements)
references
References 23 publications
0
76
0
Order By: Relevance
“…Then, L LK is calculated using (32). Subsequently, the PV voltage ripple ∆V PV is calculated solving (41)- (44) to provide the acceptable value of the PV power ripple ∆P PV . Finally, parameter C L is calculated using (40).…”
Section: Design Of the Dab Converter For Pv Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Then, L LK is calculated using (32). Subsequently, the PV voltage ripple ∆V PV is calculated solving (41)- (44) to provide the acceptable value of the PV power ripple ∆P PV . Finally, parameter C L is calculated using (40).…”
Section: Design Of the Dab Converter For Pv Applicationsmentioning
confidence: 99%
“…In the literature, the DAB converter has been used in battery energy storage systems (BESS) [34][35][36], solid-state transformers [37][38][39] and fuel cell applications [40]. Concerning PV systems, the DAB converter has been used in [39,[41][42][43][44][45][46][47][48] to interface PV arrays in series connection, but the high voltage-conversion ratio capability has not been exploited in those works. Moreover, although many design considerations have been provided for the DAB converter [32,40,49], there is not reported a design method for a PV system based on the DAB converter.…”
Section: Introductionmentioning
confidence: 99%
“…. , N ports and j = a, b, c three phases (21) For N numbers of ports per phase, the total power to be processed in three phases should be: The dc-dc ML-DAB power equation for one port is as follows. Here α, β are assumed to be constant and φ varies according to MPPT control ( Figure 3):…”
Section: Dc-link Voltage Control Using Power Mismatch Among N Portsmentioning
confidence: 99%
“…According to Femia et al, a 34‐kW boost converter with an inductance of 7.42 mH and switching frequency of 5 kHz has been designed and applied in each phase of PV system. Moreover, the dc‐link capacitance of single‐phase H‐bridge inverter is obtained from , Cdc=SgVdcVdc, where S = 37 kVA is the apparent power that flows through the single‐phase H‐bridge inverter, ω g = 120π is the fundamental angular frequency of the grid voltage, and V dc = 450V and V dc = 27V are the magnitude and maximum allowed ripple of the inverter dc‐link voltage, respectively.…”
Section: Proposed Structurementioning
confidence: 99%