High energy resolution five-crystal spectrometer for high quality fluorescence and absorption measurements on an x-ray absorption spectroscopy beamline

Abstract: Fluorescence detection is classically achieved with a solid state detector (SSD) on x-ray absorption spectroscopy (XAS) beamlines. This kind of detection however presents some limitations related to the limited energy resolution and saturation. Crystal analyzer spectrometers (CAS) based on a Johann-type geometry have been developed to overcome these limitations. We have tested and installed such a system on the BM30B/CRG-FAME XAS beamline at the ESRF dedicated to the structural investigation of very dilute sys… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
39
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 56 publications
(39 citation statements)
references
References 45 publications
0
39
0
Order By: Relevance
“…25 The energy of the incident radiation was selected using a pair of Si(220) crystals (flux of ca. 5.10 11 photons.s --1 ).…”
Section: X--ray Spectroscopymentioning
confidence: 99%
“…25 The energy of the incident radiation was selected using a pair of Si(220) crystals (flux of ca. 5.10 11 photons.s --1 ).…”
Section: X--ray Spectroscopymentioning
confidence: 99%
“…Finally, a feedback system was used to maximize the output of the two-crystal X-ray monochromator. Fluorescence detection was achieved using two spherically bent crystal analysers (Si660, 1 m bending radius) in Johann-type geometry [31,32]. A silicon drift detector (Vortex) was used for the detection of the signal reflected by the two analysers.…”
Section: Beamline Configurationmentioning
confidence: 99%
“…Total energy resolution is then limited to the intrinsic resolution of the analyzer, the energy spreading due to the Johann's geometry being minimum, the incident photon bandwidth (due to the monochromator) and the vertical size of the beam on the sample. The total energy resolution has been measured to 2.2 eV, quite far from the theoretical expected value probably due to microstrains in the silicon bent wafer as it has been already observed on bent crystal with the same radius of curvature [20].…”
Section: Additional Possibilities: Inelastic Scattering Experimentsmentioning
confidence: 91%
“…Brought to you by | New York University Bobst Library Technical Services Authenticated Download Date | 6/1/15 1:15 PM The spectrometer is a 4-crystal spectrometer adapted from the 5-crystal one installed on BM30B/CRG-FAME beamline at the ESRF [19,20]. The lower number of crystals was required because of the limited place around (KB system and in some case shielding around the sample) ( Figure 6).…”
Section: Crystal Analyser Spectrometermentioning
confidence: 99%