High-efficiency coherence-preserving harmonic rejection with crystal optics

Abstract: This work reports a harmonic-rejection scheme based on the combination of Si(111) monochromator and Si(220) harmonic-rejection crystal optics. This approach is of importance to a wide range of X-ray applications in all three major branches of modern X-ray science (scattering, spectroscopy, imaging) based at major facilities, and especially relevant to the capabilities offered by the new diffraction-limited storage rings. It was demonstrated both theoretically and experimentally that, when used with a synchrotr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 30 publications
0
3
0
Order By: Relevance
“…The much greater stability afforded by vertical crystal rotation axes enables use of higherorder crystal reflections with narrower rocking curves and hence lower minimum attainable q values. Note that, owing to dynamical scattering considerations, use of Si 220 or 440 (or many other hkl) X-ray optics while employing an Si(111) upstream monochromator results in the effective elimination of X-ray harmonics without the need for harmonic rejection mirrors (Zhang et al, 2018a). The new USAXS instrument stages operate significantly faster than the previous instrumentation, including the core USAXS flyscan operation.…”
Section: European Synchrotron Research Facility (Esrf)mentioning
confidence: 99%
“…The much greater stability afforded by vertical crystal rotation axes enables use of higherorder crystal reflections with narrower rocking curves and hence lower minimum attainable q values. Note that, owing to dynamical scattering considerations, use of Si 220 or 440 (or many other hkl) X-ray optics while employing an Si(111) upstream monochromator results in the effective elimination of X-ray harmonics without the need for harmonic rejection mirrors (Zhang et al, 2018a). The new USAXS instrument stages operate significantly faster than the previous instrumentation, including the core USAXS flyscan operation.…”
Section: European Synchrotron Research Facility (Esrf)mentioning
confidence: 99%
“…Fig. 5 summarizes results for recent and ongoing studies of AgNP sulfidation reactions (Zhang, Allen, Johnston-Peck et al, 2018) for a dilute AgNP ensemble in aqueous suspension. In this composite figure, the flow cell is shown schematically for pinhole SAXS measurements.…”
Section: In Situ and Operando Studies Using New Usaxs/saxs/ Waxs Capamentioning
confidence: 99%
“…The recorded USAXS scattering data was reduced to an absolute scale and desmeared using Indra module of SAS software. 40,41 The desmeared scattering data was then modeled with two different models to describe these complex system, which may contain multiple coexisting components e.g. 'free' particles, undecorated oil droplets, and droplets with adsorbed particles).…”
Section: Usaxs Measurements and Data Analysismentioning
confidence: 99%