2015
DOI: 10.1149/2.0471602jes
|View full text |Cite
|
Sign up to set email alerts
|

High Accuracy Concentration Analysis of Accelerator Components in Acidic Cu Superfilling Bath

Abstract: We have devised a modified cyclic voltammetry stripping (CVS) method to measure the concentrations of bis-(sulfopropyl) disulfide (SPS) and 3-mercapto-1-propane sulfonate (MPS) in Cu plating solutions. Though MPS, a breakdown product of SPS, enhances the Cu deposition rate on flat electrodes, it is not a superfilling-capable accelerator for the damascene structure, unlike SPS. Therefore, accurate measurement of SPS in damascene Cu plating baths is important. However, enhancement of the Cu deposition rate by MP… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
14
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(14 citation statements)
references
References 46 publications
0
14
0
Order By: Relevance
“…The modified linear approximation technique-cyclic voltammetry stripping (MLAT-CVS) was used for analyzing the concentration of SPS in the target Cu bath. 37 The Pt rotating disk electrode (RDE, 0.0314 cm 2 ), Pt rod, and Ag/AgCl [3 M KCl] were used as working, counter, and reference electrodes, respectively. As an intercept solution (Cu plating solution with excessive suppressor), 37 a Cu bath with pH 2, consisting of 0.125 M CuSO 4 , 0.5 M H 2 SO 4 , 0.86 M NaOH, 1 mM NaCl, and 70 mM PEG-3400, was used.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The modified linear approximation technique-cyclic voltammetry stripping (MLAT-CVS) was used for analyzing the concentration of SPS in the target Cu bath. 37 The Pt rotating disk electrode (RDE, 0.0314 cm 2 ), Pt rod, and Ag/AgCl [3 M KCl] were used as working, counter, and reference electrodes, respectively. As an intercept solution (Cu plating solution with excessive suppressor), 37 a Cu bath with pH 2, consisting of 0.125 M CuSO 4 , 0.5 M H 2 SO 4 , 0.86 M NaOH, 1 mM NaCl, and 70 mM PEG-3400, was used.…”
Section: Methodsmentioning
confidence: 99%
“…37 The Pt rotating disk electrode (RDE, 0.0314 cm 2 ), Pt rod, and Ag/AgCl [3 M KCl] were used as working, counter, and reference electrodes, respectively. As an intercept solution (Cu plating solution with excessive suppressor), 37 a Cu bath with pH 2, consisting of 0.125 M CuSO 4 , 0.5 M H 2 SO 4 , 0.86 M NaOH, 1 mM NaCl, and 70 mM PEG-3400, was used. Before analyzing, the pH of the target bath was adjusted to 2 by adding 1.73 M NaOH and 1 mM NaCl.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This study respectively predicts the concentrations of accelerator, suppressor and leveler to within 0.5%, 2.7% and 0.12% [19]. Choe et al [20] devised a modified CVS method to measure the concentration of bis-(sulfopropyl) disulfide (SPS) and 3-mercapoto-1-propane sulfonate (MPS) in Cu plating solutions. A twostep CVS analysis determines the total accelerator concentration and conversion ratio.…”
Section: Introductionmentioning
confidence: 96%
“…A twostep CVS analysis determines the total accelerator concentration and conversion ratio. The modified method allows measurement of the SPS concentration with less than 10% error [20]. Iodine ions are used as a leveling agent in the copper plating process.…”
Section: Introductionmentioning
confidence: 99%