Heterogeneously integrated impedance measuring system with disposable thin-film electrodes

Abstract: a b s t r a c tWe propose a novel integrated impedance measurement system with disposable thin-film electrodes. Most modern CMOS-based biosensors use on-chip electrodes to interface between the electronics and biosamples, which forces disposal of the CMOS chip after a few measurements, since most biological reactions are non-reversible. The sensor performance is also limited by the design of on-chip electrodes due to the physical dimensions and the CMOS design rules restrictions. In this work, we extract the e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
1
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“…This paper has demonstrated an impedance estimation read-out system with the widest frequency region, the least impedance and phase error, which is justified by Table III [9][10][11]. By integrating BIA technique with the read-out IC system, we find a better, more reliable, and quicker solution on rapid diagnostic test on cancer biomarkers.…”
Section: Discussionmentioning
confidence: 74%
“…This paper has demonstrated an impedance estimation read-out system with the widest frequency region, the least impedance and phase error, which is justified by Table III [9][10][11]. By integrating BIA technique with the read-out IC system, we find a better, more reliable, and quicker solution on rapid diagnostic test on cancer biomarkers.…”
Section: Discussionmentioning
confidence: 74%
“…The maximum value of phase angle (40°) occurred in the frequency range of 10 3 to 10 4 Hz, suggesting the frequency dispersion and the interfacial heterogeneity of the sensing layer [54]. The value of phase angle suggests that the capacitive behaviour of the sensing layer acts as an open-circuit and equals the source voltage [55]. In addition, the magnitude of the impedance gradually increased, as a common impedance response in faradaic probes.…”
Section: Resultsmentioning
confidence: 99%
“…The copyright holder for this preprint this version posted September 13, 2022. ; https://doi.org/10.1101/2022.09.11.507374 doi: bioRxiv preprint [55]. In addition, the magnitude of the impedance gradually increased, as a common impedance response in faradaic probes.…”
Section: Reproducibility Stability and Selectivity Of The Chemiresist...mentioning
confidence: 99%
“…As shown in Fig. 1a, all electrodes were surrounded by a PDMS ring to contain the electrolyte, and they were connected to an customized impedance measurement system 35 . An AC signal with the amplitude of 100 mV was used with the frequencies ranging from 10 Hz to 10 MHz.…”
Section: Sodium Chloride Concentration Measurementsmentioning
confidence: 99%