An impedance-based chemiresistor for the real-time detection of gut microbiota-generated short-chain fatty acids

Abstract: Short chain fatty acids (SCFAs) are key molecules produced by gut bacteria in the intestine, that are absorbed into the bloodstream and strongly influence human health. SCFA disruption and imbalances have been linked to many diseases; however, they are seldom used diagnostically as their detection requires extensive sample preparation and expensive equipment. In this work, an electrochemical sensor was developed to enable real time, quantitative measurement of SCFAs from complex samples in liquid phase without… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 65 publications
(77 reference statements)
0
4
0
Order By: Relevance
“…An impedimetric sensor for the real-time detection of gut-microbiota-generated SCFAs was reported by Yavarinasab et al [ 35 ]. Figure 3 displays the electrochemical platform consisting of interdigitated gold electrodes modified with ZnO and polyvinyl alcohol (PVA).…”
Section: Gastrointestinal Microbiomementioning
confidence: 99%
See 1 more Smart Citation
“…An impedimetric sensor for the real-time detection of gut-microbiota-generated SCFAs was reported by Yavarinasab et al [ 35 ]. Figure 3 displays the electrochemical platform consisting of interdigitated gold electrodes modified with ZnO and polyvinyl alcohol (PVA).…”
Section: Gastrointestinal Microbiomementioning
confidence: 99%
“… ( A ) Schematic view of the microfluidic setup and sensing layer synthesis for the determination of SCFAs and ( B ) Nyquist spectra of the sensing layer at various concentrations of acetic acid and propionic acid in a mixture with 0.5 mg mL −1 butyric acid. Adapted from [ 35 ] with permission. …”
Section: Figurementioning
confidence: 99%
“…An impedimetric sensor for the real-time detection of gut-microbiota-generated SCFAs was reported by Yavarinasab et al [33]. Figure 3 displays the electrochemical platform consisting of interdigitated gold electrodes modified with ZnO and polyvinyl alcohol (PVA).…”
Section: Gastrointestinal Microbiomementioning
confidence: 99%
“…A) Schematic view of the microfluidic setup and sensing layer synthesis for the determination of SCFAs and B) Nyquist spectra of the sensing layer at various concentrations of acetic acid and propionic acid in a mixture with 0.5 mg mL -1 butyric acid. Adapted from [33] with permission.…”
Section: Gastrointestinal Microbiomementioning
confidence: 99%