2007
DOI: 10.1016/j.chroma.2006.12.090
|View full text |Cite
|
Sign up to set email alerts
|

Heterogeneity of adsorption mechanisms in chiral normal-phase liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
7
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 36 publications
0
7
0
Order By: Relevance
“…Also, as shown by Felinger, the proper investigation of the initial region of the adsorption isotherm requires the acquisition of a large number of data points in the linear range of the isotherm, particularly if the density of high-energetic sites is low. The PM is preferred for the investigation and the interpretation of the adsorption of organic modifiers on reversed-phase adsorbent. ,, In NPLC conditions, however, this method presents a drawback due to the difficulty of detecting linear perturbation peaks of strong modifiers in columns equilibrated with a weak solvent …”
mentioning
confidence: 99%
“…Also, as shown by Felinger, the proper investigation of the initial region of the adsorption isotherm requires the acquisition of a large number of data points in the linear range of the isotherm, particularly if the density of high-energetic sites is low. The PM is preferred for the investigation and the interpretation of the adsorption of organic modifiers on reversed-phase adsorbent. ,, In NPLC conditions, however, this method presents a drawback due to the difficulty of detecting linear perturbation peaks of strong modifiers in columns equilibrated with a weak solvent …”
mentioning
confidence: 99%
“…This technique is just beginning to gain popularity in chiral chromatography. It has been used to study the adsorption of binary eluents on chiral stationary phases (CSPs) Whelk-O1 [9], DACH-ACR [10], and Chiralcel OD-I [11]. The adsorption of aqueous organic solvents was used to study the surface properties of CSPs with grafted macrocyclic antibiotics in [12,13], and the authors of [14] investigated the effect the composition of an adsorbed layer of the mobile phase has on the mechanism of amino acid retention on antibiotic columns.…”
Section: Introductionmentioning
confidence: 99%
“…Many factors can be responsible for the extent of interactions of stereoisomeric molecules with immobilized polysaccharide‐based chiral stationary phase such as dipole–dipole interactions, electrostatic forces, hydrogen bonding, hydrophobic bonding, ion–dipole interactions, steric interferences (size, orientation, and spacing of groups), and Van der Waals forces. The nature and effects of some of these factors can influence the chromatography of enantiomers …”
Section: Introductionmentioning
confidence: 99%
“…The nature and effects of some of these factors can influence the chromatography of enantiomers. 5,6 Molecular modeling studies have succeeded in interpreting many ligand-receptor mechanisms depending on the basic interactions that occur between the ligand and its site of action. Moreover, in addition, some other factors such as the binding affinity of the ligand or receptor strain have been demonstrated.…”
Section: Introductionmentioning
confidence: 99%