2015
DOI: 10.5380/ce.v20i1.37924
|View full text |Cite
|
Sign up to set email alerts
|

Hemólise De Eritrócitos Em Dispositivos De Infusão Intravenosa: Revisão Integrativa Da Literatura

Abstract: RESUMO:Hemólise extracorpórea pode ser identificada durante processos hemoterápicos. O enfermeiro é um dos profissionais responsáveis pela administração de hemocomponentes e controle de possíveis riscos, portanto deve apropriar-se de conhecimentos que respaldem a prática clínica. O objetivo foi identificar na literatura aspectos relacionados à hemólise em concentrados de hemácias decorrentes de administração de sangue por dispositivos de infusão intravenosa. Realizou-se Revisão Integrativa da Literatura. Inclu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
0
0
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 15 publications
1
0
0
1
Order By: Relevance
“…[24][25] An integrative review pointed out that hemolysis occurs during the red blood cell manipulation processes and in the passage of blood through infusion pumps and catheters. 26 Differently from the results of this research, it evidenced that hemolysis does not depend on the infusion speed, but corroborated the issue that RBC lysis always occurs as storage time increases. Another integrative review showed that there may be changes in the RBC integrity when transfused by infusion pump, showing that the volumetric pumps with cassette mechanism are the safest for this practice.…”
Section: Discussionsupporting
confidence: 40%
“…[24][25] An integrative review pointed out that hemolysis occurs during the red blood cell manipulation processes and in the passage of blood through infusion pumps and catheters. 26 Differently from the results of this research, it evidenced that hemolysis does not depend on the infusion speed, but corroborated the issue that RBC lysis always occurs as storage time increases. Another integrative review showed that there may be changes in the RBC integrity when transfused by infusion pump, showing that the volumetric pumps with cassette mechanism are the safest for this practice.…”
Section: Discussionsupporting
confidence: 40%
“…21 Cabe ressaltar que, em revisão de literatura realizada em 2015, constatou a ocorrência de hemólise ao administrar hemocomponente em bomba de infusão. 22 Com relação à alteração da taxa de KVO (estado de manutenção de veia aberta) in loco, este procedimento já pode ser executado por quem maneja a BI e se encontra descrito no manual do equipamento em análise. 17 Dúvidas ou desconhecimento dessas informações evidenciam a necessidade de treinamento contínuo dos profissionais e verificação quanto à disponibilidade de manuais correspondentes aos equipamentos em uso, com acesso facilitado para leitura e resolução de questões do cotidiano.…”
Section: Discussionunclassified