2020
DOI: 10.1016/j.jbiomech.2020.109954
|View full text |Cite
|
Sign up to set email alerts
|

Hemodynamics alteration in patient-specific dilated ascending thoracic aortas with tricuspid and bicuspid aortic valves

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 63 publications
0
5
0
Order By: Relevance
“…Although all the donors had a tricuspid aortic valve (Tab. 1), both AnevPrim2 and AnevPrim3 donors had aortic valve dysfunctions (AnevPrim3 donor harbored a mechanical prosthesis) inducing significant hemodynamic disturbance, which are traditionally typical of bicuspid aortic valves, and which were shown to induce significant remodelling in the aortic wall (Guzzardi et al 2015;Michel et al 2018;Jayendiran et al 2020).…”
Section: Differences Between Healthy and Aneurysmal Smcsmentioning
confidence: 99%
“…Although all the donors had a tricuspid aortic valve (Tab. 1), both AnevPrim2 and AnevPrim3 donors had aortic valve dysfunctions (AnevPrim3 donor harbored a mechanical prosthesis) inducing significant hemodynamic disturbance, which are traditionally typical of bicuspid aortic valves, and which were shown to induce significant remodelling in the aortic wall (Guzzardi et al 2015;Michel et al 2018;Jayendiran et al 2020).…”
Section: Differences Between Healthy and Aneurysmal Smcsmentioning
confidence: 99%
“…The hemodynamic patterns depend on the blood flow eccentricity at the aortic root regardless of the aortic valve phenotype [ 43 ]. The blood flow vortices produce the excessive mechanical stresses at certain aortic wall locations, which further become the foci of the dilatation and, eventually, they become the entry sites for acute aortic dissections in patients with aortic arch variants.…”
Section: Biomechanical Properties Of Ascending Aortamentioning
confidence: 99%
“…13 Ascending Aorta Computational Fluid Dynamics (CFD) is a well known engineering tool used in a wide range of applications which has recently been considered for use in medical applications. It has quickly become an invaluable tool and has been used to achieve multiple advances and breakthroughs 17,18 . A framework was determined to use patient-specific CFD to improve the design of prosthetic heart vales and the implantation procedures 17 , whilst research also used patient-specific CFD to conclude that eccentricity at the aortic root is a major determinant of the haemodynamic patterns in ascending thoracic aortic aneurysm patients 18 .…”
Section: Studymentioning
confidence: 99%