2006
DOI: 10.1016/j.injury.2006.06.008
|View full text |Cite
|
Sign up to set email alerts
|

Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: A biomechanical evaluation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

3
124
0
4

Year Published

2012
2012
2020
2020

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 194 publications
(132 citation statements)
references
References 11 publications
3
124
0
4
Order By: Relevance
“…Positioning of the intramedullary device close to the weightbearing axis of the femur reduces forces on the implant. The primary innovation of the proximal femoral nail antirotation (PFNA, AO/ASIF) design is the helical neck blade that reduces the risk of bone loss and offers improved purchase in the femoral head as a result of compaction of cancellous bone around the blade during insertion [35,36,41]. Rotation of the head-blade combination as a whole is prevented by an intrinsic locking mechanism [3,38].…”
Section: Introductionmentioning
confidence: 99%
“…Positioning of the intramedullary device close to the weightbearing axis of the femur reduces forces on the implant. The primary innovation of the proximal femoral nail antirotation (PFNA, AO/ASIF) design is the helical neck blade that reduces the risk of bone loss and offers improved purchase in the femoral head as a result of compaction of cancellous bone around the blade during insertion [35,36,41]. Rotation of the head-blade combination as a whole is prevented by an intrinsic locking mechanism [3,38].…”
Section: Introductionmentioning
confidence: 99%
“…Next, each specimen was cyclically loaded, with 750 N vertical loads applied at a rate of 3 Hz for 10, 100, 1000, and 10,000 cycles. Each specimen was allowed to reach equilibrium (120 s) after each cyclic interval, and displacement measurements both loaded and unloaded were taken 23. Finally, each specimen was axially loaded to failure recorded in load displacement curve.…”
Section: Methodsmentioning
confidence: 99%
“…Only 04% patient had poor range of movements. Strauss et al showed that in 49 patients treated with PFN, the walking ability and squatting ability was completely restored in almost all the cases at 6 months follow up post operatively [24] . No limp was present in 92% of patients in our series at final follow up & were able to use the stairs without any problem.…”
Section: Complicationsmentioning
confidence: 99%