2009
DOI: 10.1016/j.cnsns.2009.01.009
|View full text |Cite
|
Sign up to set email alerts
|

Heat and mass transfer in liquid desiccant air-conditioning process at low flow conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(7 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…To realize the effective and stable operation of system, it requires reliable control of the dehumidifier [1], which relies greatly on accurate prediction of their transient response. However, the previous studies mainly focused on the steady-state heat and mass transfer processes, and research in the aspect of transient performance was still very limited for the dehumidifier [2][3][4]. Therefore, in the present paper, a dynamic model was developed to render the predication of the transient response performance of the dehumidifier.…”
Section: Introductionmentioning
confidence: 99%
“…To realize the effective and stable operation of system, it requires reliable control of the dehumidifier [1], which relies greatly on accurate prediction of their transient response. However, the previous studies mainly focused on the steady-state heat and mass transfer processes, and research in the aspect of transient performance was still very limited for the dehumidifier [2][3][4]. Therefore, in the present paper, a dynamic model was developed to render the predication of the transient response performance of the dehumidifier.…”
Section: Introductionmentioning
confidence: 99%
“…The results show that 6-3-3-1 ANN structure was the best model for predicting the watercondensation rate, where as the 6-6-6-1 was the best model for predicting the dehumidifier effectiveness. Local volumetric average approach wasusedbyPengandPan [7] to investigate the transient heat and mass transfer in liquid desiccant air-conditioning process at low flow conditions.…”
Section: Introductionmentioning
confidence: 99%
“…Gandhidasan et al [17] investigated the transient behavior of a gauze-type structured packing liquid desiccant dehumidifier. More recently, Peng and Pan [18] used a local volumetric average approach to develop a transient one-dimensional model of a liquid desiccant process at low flow conditions. The results were compared with the measurements at a experimental test stand filled with plastic pall ring packing material.…”
Section: List Of Symbolsmentioning
confidence: 99%