Heart rate detection from an electronic weighing scale

Abstract: We propose a novel technique for beat-to-beat heart rate detection based on the ballistocardiographic (BCG) force signal from a subject standing on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear and does not require any sensors attached to the body because it uses the load cells in the scale. We have devised an approach to estimate the sensitivity and frequency response of three commercial weigh… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
34
1
7

Year Published

2011
2011
2019
2019

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 56 publications
(44 citation statements)
references
References 19 publications
1
34
1
7
Order By: Relevance
“…The effect of phase response was quantified by filtering the reference signals by some simulated filters that have been used or could be used in analog front-ends for BCG acquisition: 1 st order [4,11], 2 nd order Butterworth [10] and 2 nd order Bessel. The timing displacement Δt i of each J peak i on the filtered signals with respect to the reference was measured and, as the effect of phase response is systematic, only E(Δt) was analyzed.…”
Section: Effect Of Phase Response Sampling Frequency Number Of Bitsmentioning
confidence: 99%
See 3 more Smart Citations
“…The effect of phase response was quantified by filtering the reference signals by some simulated filters that have been used or could be used in analog front-ends for BCG acquisition: 1 st order [4,11], 2 nd order Butterworth [10] and 2 nd order Bessel. The timing displacement Δt i of each J peak i on the filtered signals with respect to the reference was measured and, as the effect of phase response is systematic, only E(Δt) was analyzed.…”
Section: Effect Of Phase Response Sampling Frequency Number Of Bitsmentioning
confidence: 99%
“…Nevertheless, this is not the case of the J peak, for which the influence of sources of uncertainty already considered in the detection of the R peak of the ECG, such as the minimal system bandwidth as well as others that can introduce significant systematic and random timing displacements [15] are still to be analyzed. With regard to system bandwidth, some high-pass cutoff frequencies for BCG found in the published work are 0.1 Hz [4,10], 0.2 Hz [5], 0.5 Hz [11] and 1 Hz [6]. Even though the BCG spectrum probably extends to these low frequencies, slow balance-related motion and respiration artifacts dominate in these bands for standing BCG recordings.…”
Section: Introductionmentioning
confidence: 96%
See 2 more Smart Citations
“…Recientemente se ha registrado el BCG en una variedad de ambientes, para lo cual se han desarrollado sistemas de medida basados en sillas [3], [4], camas [5], básculas de baño [6] y algunos portables en ropa [7].…”
Section: Unidadesunclassified