2021
DOI: 10.1016/j.zemedi.2020.05.006
|View full text |Cite
|
Sign up to set email alerts
|

“Harmonization” of donor and recipient tomography in corneal transplantation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0
2

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 9 publications
0
2
0
2
Order By: Relevance
“…All these functionalities run in an integrated and simultaneous sequence after a single imaging, which supports the efficiency of this semi-automated method in comparison to a manual CCT measurement or a single central cross-line scan. In the future, curvature mapping could allow to orient the transplant during the surgery in order to align the steep and flat meridians of donor and recipient together and thus minimize postoperative astigmatism (''harmonization'' of donor and recipient tomography) (Ma ¨urer et al 2021). Until today, this self-programmed MATLAB software was used to analyze raw data from 3DV-files from CASIA or CASIA 2 AS-OCT (Tomey, Nagoya, Japan) and from AVI-files from Spectralis AS-OCT (Heidelberg Engineering, Heidelberg, Germany).…”
Section: Resultsmentioning
confidence: 99%
“…All these functionalities run in an integrated and simultaneous sequence after a single imaging, which supports the efficiency of this semi-automated method in comparison to a manual CCT measurement or a single central cross-line scan. In the future, curvature mapping could allow to orient the transplant during the surgery in order to align the steep and flat meridians of donor and recipient together and thus minimize postoperative astigmatism (''harmonization'' of donor and recipient tomography) (Ma ¨urer et al 2021). Until today, this self-programmed MATLAB software was used to analyze raw data from 3DV-files from CASIA or CASIA 2 AS-OCT (Tomey, Nagoya, Japan) and from AVI-files from Spectralis AS-OCT (Heidelberg Engineering, Heidelberg, Germany).…”
Section: Resultsmentioning
confidence: 99%
“…The method lasts about 12 minutes -2 minutes for measurement and 10 minutes for evaluation. In the future, sterile donor tomography could enable: (1) the harmonisation of donor and recipient tomography [23,24], poten-tially minimising persistent residual astigmatism after suture removal for a particular donor-recipient pair; and (2) the improvement of the IOL power calculation in a classical triple procedure by means of regression analysis between pre-and postoperative total refractive power of donor corneal tissues [25]. These projects are currently being researched in Homburg/Saar.…”
Section: Discussionmentioning
confidence: 99%
“…A trepanação do botão corneano do doador acima de 8mm apresentou associação estatística significativa com a incidência das complicações intraoperatórias, como demonstraram estudos realizados no Brasil e Nova Zelândia. Um estudo alemão apontou que a "harmonização" da aplicabilidade entre tecido doador e receptor foi realizada por meio da medição com o uso da tomografia de coerência óptica do segmento anterior Casia 2, no intuito de reduzir o astigmatismo residual após o transplante corneano (CRUZ et al, 2019;MEYER et al, 2016;MÄURER;SEITZ;LANGENBUCHER, 2020).…”
Section: Característicasunclassified