2021
DOI: 10.1109/access.2020.3037126
|View full text |Cite
|
Sign up to set email alerts
|

Hardware-in-the-Loop Implementation of Projectile Target Search Algorithm for Selective Harmonic Elimination in a 3-Phase Multilevel Converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

6
3

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 30 publications
(32 reference statements)
0
12
0
Order By: Relevance
“…(16) Also from eq. (8) < 4 ( ( 1 ) is less than 1) Hence 4 > 1 (As maximum value of is 1) Or > 1 4 (17) Similarly other constraints can be found out. Eq.…”
Section: B 9-level Outputmentioning
confidence: 86%
See 1 more Smart Citation
“…(16) Also from eq. (8) < 4 ( ( 1 ) is less than 1) Hence 4 > 1 (As maximum value of is 1) Or > 1 4 (17) Similarly other constraints can be found out. Eq.…”
Section: B 9-level Outputmentioning
confidence: 86%
“…The proposed technique has the advantage of equal power distribution in modules [16] as well as low THD in output voltage. The authors in [17] have proposed an 11 level MLI topology that utilizes SHE for the removal of lower-order odd harmonics. A projectile target algorithm is used to solve the non-linear transcendental equations.…”
Section: Introductionmentioning
confidence: 99%
“…S is the number of steps, and M represents the modulation index. The ratio between the fundamental component's magnitude and the maximum achievable magnitude is given by (8).…”
Section: Problem Formulationmentioning
confidence: 99%
“…In recent times, multilevel inverters (MLIs) have been used as a potential solution for DC to AC conversion for various applications such as renewable energy conversion systems, high power drives, a high-voltage direct current (HVDC) transmission system, a distributed power generation system, etc. The main advantages of MLIs are lower dv/dt stress, higher operating voltage with lower rating devices, and near to sinusoidal output voltage, which in turn reduces total harmonic distortion (THD) and fault-tolerant capability [1][2][3]. Conventional MLIs such as the neutral point clamped (NPC) inverter, flying capacitor (FC) inverter, cascaded H-bridge (CHB) inverter, and modular multilevel converter (MMC) have replaced the conventional two-level inverter for medium and high voltage applications [4,5].…”
Section: Introductionmentioning
confidence: 99%