2021
DOI: 10.3390/s21206823
|View full text |Cite
|
Sign up to set email alerts
|

Hardware Implementation and RF High-Fidelity Modeling and Simulation of Compressive Sensing Based 2D Angle-of-Arrival Measurement System for 2–18 GHz Radar Electronic Support Measures

Abstract: This article presents the hardware implementation and a behavioral model-based RF system modeling and simulation (M&S) study of compressive sensing (CS) based 2D angle-of-arrival (AoA) measurement system for 2–18 GHz radar electronic support measures (RESM). A 6-channel ultra-wideband RF digital receiver was first developed using a PXIe-based multi-channel digital receiver paired with a 6-element random-spaced 2D cavity-backed-spiral-antenna array. Then the system was tested in an open lab environment. The… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
7
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(7 citation statements)
references
References 40 publications
0
7
0
Order By: Relevance
“…The parameters used in the study were (1) ADC sampling frequency was at 2.56 GHz, (2) since the real samples were used in the FFT, the single-tone CW signal frequency was randomly picked within 100 and 1180 MHz in each calculation, hence the DRX IBW was about 1080 MHz, and (3) the data lengths used in FFT were from 2 5 to 2 20 . The signal detection in this study was defined as not only the peak signal in a frequency-bin being higher than the threshold, but also the frequency-bin location should be within ±3 bins of the input signal frequency.…”
Section: Signal Detection From Fft-based Drx With Different Number Of...mentioning
confidence: 99%
See 4 more Smart Citations
“…The parameters used in the study were (1) ADC sampling frequency was at 2.56 GHz, (2) since the real samples were used in the FFT, the single-tone CW signal frequency was randomly picked within 100 and 1180 MHz in each calculation, hence the DRX IBW was about 1080 MHz, and (3) the data lengths used in FFT were from 2 5 to 2 20 . The signal detection in this study was defined as not only the peak signal in a frequency-bin being higher than the threshold, but also the frequency-bin location should be within ±3 bins of the input signal frequency.…”
Section: Signal Detection From Fft-based Drx With Different Number Of...mentioning
confidence: 99%
“…The details of the threshold calculation can be found in the Chapter 6 of [9], which will also be briefly discussed in Section 5, when we develop the time-slot-based thresholds for AIRS. Figure 1 shows the calculated thresholds for P f as of 10 −7 versus the length of FFT from 2 5 to 2 20 . Using the parameters given above, Figure 2 shows the POD with P f as of 10 −7 , when the Input-SNR before FFT is against different lengths of FFT.…”
Section: Signal Detection From Fft-based Drx With Different Number Of...mentioning
confidence: 99%
See 3 more Smart Citations