Hardness measured with traditional Vickers and Martens hardness methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
67
0
5

Year Published

2009
2009
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 144 publications
(88 citation statements)
references
References 22 publications
5
67
0
5
Order By: Relevance
“…Similarly IPS-ED demonstrated similar values to the ones given by Bauer & Illie [1]. The differences in HV values might be appended to the different loading conditions (2.94 N compared to 9.8 N) and the possible implication of indentation size effect (ISE), a complication where the hardness testing tends to over-or underestimate Vickers values [17] below a threshold, which is dependent of the material type. Indentation modulus of ZNano was found to be close to the value given by the manufacturer (9 GPa) [11], and IPS-ED to 7.1 given by Bauer & Illie [1].…”
Section: Discussionsupporting
confidence: 53%
See 1 more Smart Citation
“…Similarly IPS-ED demonstrated similar values to the ones given by Bauer & Illie [1]. The differences in HV values might be appended to the different loading conditions (2.94 N compared to 9.8 N) and the possible implication of indentation size effect (ISE), a complication where the hardness testing tends to over-or underestimate Vickers values [17] below a threshold, which is dependent of the material type. Indentation modulus of ZNano was found to be close to the value given by the manufacturer (9 GPa) [11], and IPS-ED to 7.1 given by Bauer & Illie [1].…”
Section: Discussionsupporting
confidence: 53%
“…These two different expressions of the same property were selected for the following reasons: HM is derived by a fully automated procedure overcoming parameters affecting the accuracy of HV (i.e. resolution of optical system, operator's perception, rebound of material around the indentation and others [17], however there is no data for HM in dental literature and thus HV was selected for comparisons with previous studies.…”
Section: Discussionmentioning
confidence: 99%
“…The second factor contributing to the ISE effect is caused by the properties of the materials. Shahdad et al 28 discussed the ISE effect associated with elastic recovery after indenter removal, and elastic-plastic deformation under the indenter, particularly at low test loads, and that there can be further complications if it occurs in brittle materials. They found that none of the ISE models can be accepted as the best to describe the ISE in different types of materials 10 .…”
Section: Discussionmentioning
confidence: 99%
“…The indenter displacement of the definite test frame represented the total amount of the elastic deformation of the surface along with the plastic depth of the impression. 30 All specimens were tested 3 times, and the values of HM and E IT were calculated (TestXpert V12.3 Master; Zwick) with the following equations (DIN EN ISO 14577) 35 : and Descriptive statistics were calculated, and the normality of data distribution was tested using the Kolmogorov-Smirnov and Shapiro-Wilk test. The Levene test was used to evaluate the assumption of variances' homogeneity.…”
Section: Methodsmentioning
confidence: 99%
“…5,28 Martens hardness enables a physicomechanical characterization of the local mechanical properties of materials, including the elastic and plastic parts under different loading regimens. 29,30 Most of the available studies, however, only determined the reduced mechanical properties of resins after aging in artificial saliva, alcohol, and distilled water. 31,32 To date, only limited information is available on the long-term behavior of contemporary polymers such as PEEK with regard to different aging regimens.…”
Section: Introductionmentioning
confidence: 99%