2004
DOI: 10.3354/dao061113
|View full text |Cite
|
Sign up to set email alerts
|

Haemolymph [Na+] and [Cl-] loss in Gammarus fossarum exposed in situ to a wide range of acidic streams

Abstract: The acid-sensitive amphipod Gammarus fossarum was exposed in situ for 24, 96 and 168 h to 18 streams (9 draining from granite and 9 draining from sandstone bedrock), selected in order to provide a wide range of acidification. After 24 h, exposure to slightly acidic (6.00 ≤ pH ≤ 5.50) and strongly acidic water (pH < 5.50) led to a severe and significant depletion in haemolymph [

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2006
2006
2015
2015

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 44 publications
1
6
0
Order By: Relevance
“…Sodium concentrations in haemolymph were evaluated using atomic absorption spectrophotometry (Perkin Elmer Analyst 100) whereas chlorides were measured by ionic chromatography (Dionex 4500i equipped with an Ion Pac AS4A column). Further details on haemolymph sampling and analysis are available in [33].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Sodium concentrations in haemolymph were evaluated using atomic absorption spectrophotometry (Perkin Elmer Analyst 100) whereas chlorides were measured by ionic chromatography (Dionex 4500i equipped with an Ion Pac AS4A column). Further details on haemolymph sampling and analysis are available in [33].…”
Section: Methodsmentioning
confidence: 99%
“…As a result, Na + and Cl − which are known to make up to 90% or more of the haemolymph osmotic pressure in most crustaceans [30], can be impaired by chemical stress (e.g. zinc [31]; copper [32]; cadmium [17]; acidification [33]). Osmoregulation is an important and highly energy-consuming regulatory function in aquatic invertebrates.…”
Section: Introductionmentioning
confidence: 99%
“…For the gammarids, after drying on filter paper, samples of haemolymph were taken from the telson of each individual (n=10) using a gauged 5-µl capillary. The capillaries were centrifuged for 5 min at 6,660 g. After centrifugation, the haemolymph volume was determined, diluted in 2 ml of MQ water and kept at 4°C before analysis (Felten and Guerold, 2004). Chloride concentrations were determined by ionic chromatography (Dionex 4500i equipped with a Ion Pac AS4A column) whereas sodium and calcium concentrations were measured by atomic absorption spectrometry (Perkin Elmer Analyst 100) (Felten et al, 2008).…”
Section: Analysis Of Haemolymph CL - Na + and Ca 2+ Concentrationsmentioning
confidence: 99%
“…Surprisingly, and despite the numerous papers reporting detrimental effects of acidification on macroinvertebrate communities, few realistic studies have been performed to assess the ecophysiology of smaller acid-sensitive species and finally, relatively little is known about their physiological responses to short-term acid stress. In previous studies (Felten & Guérold, 2001, 2004, we showed that Gammarus fossarum (Crustacea: Amphipoda), a common acidsensitive species in west Palearctica, also sustained a severe depletion of haemolymph Na + and Clions when exposed to acidic conditions. Conjointly, we determined relationship between acidification level and haemolymph ion losses (Felten & Guérold, 2004).…”
Section: Introductionmentioning
confidence: 95%
“…In previous studies (Felten & Guérold, 2001, 2004, we showed that Gammarus fossarum (Crustacea: Amphipoda), a common acidsensitive species in west Palearctica, also sustained a severe depletion of haemolymph Na + and Clions when exposed to acidic conditions. Conjointly, we determined relationship between acidification level and haemolymph ion losses (Felten & Guérold, 2004).…”
Section: Introductionmentioning
confidence: 95%