2006
DOI: 10.1088/1742-6596/32/1/027
|View full text |Cite
|
Sign up to set email alerts
|

Ground based 2DoF test for LISA and LISA PF

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2010
2010
2015
2015

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…free from any experimenter's intervention, along the sensitive direction (the one that faces the opposite, far TM in the interferometer arm), while motion in all other degrees of freedom (DOFs) will be restrained by feedback, to keep both TM centered inside one spacecraft [7]. To address this issue, we are completing a complementary instrument, nicknamed PETER (PEndolo Traslazionale E Rotazionale, Rotational and Translational Pendulum) [8]: a double torsion pendulum where force-free motion is to be achieved simultaneously in two different DOFs, i.e. for translation of the TM and for rotation around its axis.…”
Section: Experimental Set Up and Measurementsmentioning
confidence: 99%
“…free from any experimenter's intervention, along the sensitive direction (the one that faces the opposite, far TM in the interferometer arm), while motion in all other degrees of freedom (DOFs) will be restrained by feedback, to keep both TM centered inside one spacecraft [7]. To address this issue, we are completing a complementary instrument, nicknamed PETER (PEndolo Traslazionale E Rotazionale, Rotational and Translational Pendulum) [8]: a double torsion pendulum where force-free motion is to be achieved simultaneously in two different DOFs, i.e. for translation of the TM and for rotation around its axis.…”
Section: Experimental Set Up and Measurementsmentioning
confidence: 99%
“…The chamber is continuously driven by the seismic noise, which disturbs the pendulum or balance, and thus limits the experimental resolution to a certain level. A simplified model, as shown in figure 1, is used to conveniently analyse the disturbances contributing to the horizontal seismic noise [8,9,12]. A balance bar and a PM are suspended by two fibres.…”
Section: Estimation Of the Seismic Noise Limitmentioning
confidence: 99%
“…For the two-stage torsion pendulum of Stanga et al [8,9], the CMRR can be deduced with a similar method in spite of the four-mass configuration, which is estimated to be 20 log |T m /H m | ω<ω L ≈ −107 dB at low frequencies. It means that the local horizontal seismic noise with an order of 10 −7 m s −2 Hz −1/2 will limit the ground-based performance measurements of the translational DOF to about 4 × 10 −13 m s −2 Hz −1/2 .…”
Section: Estimation Of the Seismic Noise Limitmentioning
confidence: 99%