2011
DOI: 10.2478/v10175-011-0060-8
|View full text |Cite
|
Sign up to set email alerts
|

Grid synchronization and symmetrical components extraction with PLL algorithm for grid connected power electronic converters - a review

Abstract: Abstract. In this paper, a review of Phase Locked Loop (PLL) algorithms and symmetrical component extraction methods intended for grid-connected power electronic converters are presented. Proposed classification is based on voltage representation in three coordinates: natural (abc), stationary (αβ) and rotating coordinates (dq). The three selected algorithms are described in details: Dual Second Order Generalized Integrator (DSOGI-PLL), Dual Virtual Flux -both in stationary coordinates. The third one, in rotat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
29
0
3

Year Published

2015
2015
2020
2020

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 54 publications
(47 citation statements)
references
References 33 publications
(39 reference statements)
0
29
0
3
Order By: Relevance
“…Energies 2017, 10, 1528 7 of 17 with: (25) where m and n represent the oscillating amplitude coefficient (OAC) of active and reactive power ripples. The advantage of this power compensation method is that the use of NS current components is not required as they are often very small and large errors may be produced, when compared with using of the PS current components.…”
Section: Power Reference Derivationmentioning
confidence: 99%
See 1 more Smart Citation
“…Energies 2017, 10, 1528 7 of 17 with: (25) where m and n represent the oscillating amplitude coefficient (OAC) of active and reactive power ripples. The advantage of this power compensation method is that the use of NS current components is not required as they are often very small and large errors may be produced, when compared with using of the PS current components.…”
Section: Power Reference Derivationmentioning
confidence: 99%
“…To obtain the instantaneous power outputs and compensations, the PS and NS components of system voltage and current are required. The equations used for sequence component extraction are [24,25]: …”
Section: Structure Of the Irsmc Dpc Strategymentioning
confidence: 99%
“…For the 3-φ VSI-based distributed generation system, the commonly investigated and implemented GS methods [4], [8], [28] can be broadly classified as given in Table I. The methods presented in Table I, are suitable to be used to control one MS with VSI to achieve the grid synchronization.…”
Section: Review Of Grid Synchronization Techniquesmentioning
confidence: 99%
“…However, in a usual distorted voltage condition, the frequency detection by this method can lead to significant errors [6]. Therefore, for practical applications, a frequency estimator based on zero crossing is unsuitable.…”
Section: A New Approach To the Adaptive Gdsc-pllmentioning
confidence: 99%