2022
DOI: 10.1016/j.heliyon.2022.e09259
|View full text |Cite
|
Sign up to set email alerts
|

Green-synthesized, pH-stable and biocompatible carbon nanosensor for Fe3+: An experimental and computational study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 62 publications
0
8
0
Order By: Relevance
“…Furthermore, the broad satellite peak at 856.7 eV is owned by Ni 2p 3/2 of Ni 3+ , and the peak at 874.5 eV belongs to Ni 2p 1/2 of Ni 2+ . The C 1s signal reveals two peaks that appeared at 285.3 and 287.7 eV, corresponding to C–H and CO/CN (Figure c). Also, for O 1s spectra, three peaks at 530.1, 532.0, and 533.45 eV were attributed to CO, C–OH, and C–O–C (Figure d) …”
Section: Resultsmentioning
confidence: 98%
See 1 more Smart Citation
“…Furthermore, the broad satellite peak at 856.7 eV is owned by Ni 2p 3/2 of Ni 3+ , and the peak at 874.5 eV belongs to Ni 2p 1/2 of Ni 2+ . The C 1s signal reveals two peaks that appeared at 285.3 and 287.7 eV, corresponding to C–H and CO/CN (Figure c). Also, for O 1s spectra, three peaks at 530.1, 532.0, and 533.45 eV were attributed to CO, C–OH, and C–O–C (Figure d) …”
Section: Resultsmentioning
confidence: 98%
“…Also, for O 1s spectra, three peaks at 530.1, 532.0, and 533.45 eV were attributed to C�O, C− OH, and C−O−C (Figure 5d). 37 Electrochemical Measurement. The performance of the HNNS electrocatalyst for OER was investigated in an alkaline medium (1 M KOH) utilizing electrochemical workstation (Meterohm Autolab PGSTAT204 potentiostat/galvanostat) in a three-electrode system.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Studies show that species with a lower energy gap have higher reactivity and therefore higher absorption energy (Figure 11 and Table 2). [43][44][45] The results show that the sensor energy gap in the presence of Hg 2 + cation is minimized. This is while there was no significant change in the energy gap in the presence of other cations.…”
Section: Molecular Electronic Properties Energy Gapmentioning
confidence: 90%
“…Studies show that species with a lower energy gap have higher reactivity and therefore higher absorption energy (Figure 11 and Table 2). [43–45] …”
Section: Methodsmentioning
confidence: 99%
“…Photoluminescent nanomaterials like carbon dots (CDOTs) have potential for simple and rapid sensing of metal ions. For instance, Wu et al have reported a fluorescence turn-off method for detection of Fe­(III) where the fluorescence intensity of CDOTs decreases with an increase in Fe­(III) concentration with the linear relationship in the range of 0.1–2 mM and a limit of detection (LOD) of 0.57 μM . CDOTs and their composites have also been bestowed for the detection of GSH.…”
Section: Introductionmentioning
confidence: 99%