2019
DOI: 10.1109/tdei.2019.007989
|View full text |Cite
|
Sign up to set email alerts
|

Grading of electric field distribution of AC polymeric outdoor insulators using field grading material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 36 publications
(12 citation statements)
references
References 20 publications
0
12
0
Order By: Relevance
“…Materials with nonlinear dielectric behaviors are applied to rotating electrical machines for the control of the electrical field strength in the insulation system of stator end windings [ 28 ]. Nonlinear conductive materials enable the grading of electric-field distributions in polymeric outdoor insulators, particularly near the high-voltage and ground terminals [ 125 ]. It is also possible to find nonlinear materials in cable accessories [ 22 , 36 , 61 ], such as cable joints and HVDC cable terminations ( Figure 50 ) [ 37 , 126 ].…”
Section: Current Applications Of Nonlinear Polymer Composites In Hv Engineeringmentioning
confidence: 99%
“…Materials with nonlinear dielectric behaviors are applied to rotating electrical machines for the control of the electrical field strength in the insulation system of stator end windings [ 28 ]. Nonlinear conductive materials enable the grading of electric-field distributions in polymeric outdoor insulators, particularly near the high-voltage and ground terminals [ 125 ]. It is also possible to find nonlinear materials in cable accessories [ 22 , 36 , 61 ], such as cable joints and HVDC cable terminations ( Figure 50 ) [ 37 , 126 ].…”
Section: Current Applications Of Nonlinear Polymer Composites In Hv Engineeringmentioning
confidence: 99%
“…the development of novel pulsed power technology. Examples include various geometrical modifications to existing system accessories, the use of surface grading through conductive coatings [1], [2], or the use of field-adaptive grading materials [3]- [6].…”
Section: Introductionmentioning
confidence: 99%
“…Timely replacement of insulators with cracks can eliminate hidden troubles, while it cannot fundamentally manage the continuous occurrence of sheath tearing [18,19]. Therefore, it is urgent to conduct a systematic analysis of the tearing problem of high-speed train roof silicone rubber insulator sheath.…”
Section: Introductionmentioning