1998
DOI: 10.1016/s0003-9993(98)90038-7
|View full text |Cite
|
Sign up to set email alerts
|

Goniometric assessment of shoulder range of motion: Comparison of testing in supine and sitting positions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
74
0
3

Year Published

2004
2004
2024
2024

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 118 publications
(84 citation statements)
references
References 14 publications
0
74
0
3
Order By: Relevance
“…The reproducibility of the various devices used to assess shoulder ROM has been evaluated in several studies. [10][11][12][13][14][15][16][17][18][19] Although in clinical practice ROM assessment is often based on visual inspection of the movement, insight into the reproducibility of the visual estimation of shoulder ROM is limited. 20,21 The level of reproducibility of ROM measurement may be influenced by many factors such as the instruments and procedures applied, the joint examined, or the type of movement tested.…”
Section: By American Congress Of Rehabilitation Medicine and The Amermentioning
confidence: 99%
“…The reproducibility of the various devices used to assess shoulder ROM has been evaluated in several studies. [10][11][12][13][14][15][16][17][18][19] Although in clinical practice ROM assessment is often based on visual inspection of the movement, insight into the reproducibility of the visual estimation of shoulder ROM is limited. 20,21 The level of reproducibility of ROM measurement may be influenced by many factors such as the instruments and procedures applied, the joint examined, or the type of movement tested.…”
Section: By American Congress Of Rehabilitation Medicine and The Amermentioning
confidence: 99%
“…Several methods have been used to assess the alignment of body segments, such as visual analysis, X-rays 16 , video cameras 6,7,[18][19][20] and goniometry [21][22][23][24][25] . The use of photography as a postural record is recommended for its simplicity and low cost and for the possibility of creating a database to follow postural development 6 and, therefore, observe subtle modifications 24,[26][27][28] .…”
Section: Introductionmentioning
confidence: 99%
“…18 The center of the goniometer was placed on the posterior glenohumeral joint 19 with one arm perpendicular to the floor and the other aligned according to the angle of the proximal humerus. 20 For ER, the patient had their elbow flexed at 90 degrees with their humerus on the side.…”
Section: Rom Assessmentmentioning
confidence: 99%